background image

5

D) Configuration of Relay Outputs

E) Personal Safety

F) Door Forced-Open-Alarm & Visitor Announcing

G) Allowable Door-Left-Open Time for Door-Open-Too-Long Alarm

-- Installer Programming

-- Installer Programming

-- Installer Programming

-- Installer Programming

40

#

41

#

42

#

50

#

51

#

52

#

60

#

61

#

62

#

70

#

71

#

72

#

76

#

80

#

81

#

82

#

83

#

9

#

9

#

1 to 999

Output 1 in Momentary Mode from 1 to 999 seconds

Output 1 in Start/Stop Mode without accelerated code

Output 1 in Start/Stop Mode with accelerated code

1 to 999

Output 2 in Momentary Mode from 1 to 999 seconds

Output 2 in Start/Stop Mode without accelerated code

Output 2 in Start/Stop Mode with accelerated code

1 to 999

Output 3 in Momentary Mode from 1 to 999 seconds

Output 3 in Start/Stop Mode without accelerated code

Output 3 in Start/Stop Mode with accelerated code

After 10 successive false codes, the keypad locks during
30 seconds
After 10 successive false codes, the Duress Output
switches to ground

5 to 10

Selectable of 5 to 10 successive false codes, the keypad
locks during 15 minutes. The keypad can be reset to
release locking with the Master Code at any time during
the locking period

00

Disappearance of all the above securities

Door Forced-Open-Alarm detection is Disabled

Door Forced-Open-Alarm detection is Enabled

Visitor announcing chime is given if the User Code in Group 1 is not keyed in first
when the door is opened.
Visitor announcing chime is always given when the door is opened

0

The timer is Disabled. Allows the door an infinite time to open for

1 to 999

Allowable time from 1 to 999 seconds for door open before the
Door-Open-Too-Long alarm is triggered

Access Keys Code Duration

Access Keys Number of False Entry

Validation

Comments

Access Keys Validation Comments

Access Keys Code Duration Validation Comments

Validation Comments

6

H) Exit Programming Mode

The Default Values

*

Keypad exits programming mode and returns to normal operation

Single User Mode if it is your selection.

Output 2 is 1 Second Momentary Mode

601 --- Output 3 is 1 Second Momentary Mode
70 ----- After 10 Successive False Code, The Keypad Locks During 30 Seconds
80 ----- Door Force-Open-Alarm Detection is Disabled
90 ----- The Door Open-Too-long Timer is Disabled

The mode of

for each output only allow

User Code for each output, and it is fixed to 4

digits. This mode is prepared for those people DO NOT like to Press the

for code entry to activate the output.

They only press the 4 digits User Code, then, the specific output is activated. Each output has its own code.

SINGLE USER OR MULTI-USERS SELECTION

The keypad consists two sets of application software for owner's selection in user code programming. One is
"Single User Code for Each Output" and the other is "Multi-User Codes for Each Output".

The keypad has been set with a Master Code of "0000" and Multi User Mode with the following "Default Values" at
the factory. You do not require to make any operation mode change if your selection is Multi-User Mode. However,
You have to refresh the system to

0000

401 --- Output 1 is 1 Second Momentary Mode
501 ---

The Single User Code

Single User Code

ONE

!

!

!

Validation

Comments

#

#

The Multi-User Codes

Code Entry Limitation for Multi-User Codes

The mode of

is prepared for setting up a group of user codes for each output. The User Codes can be

4 to 8 digits. To activate the desired output, the user has to press the

key to confirm of code entry in the

operation of the Multi-User Code. The following are the number of User Codes available in each group:

User Codes in Group 1 for Output 1 --- 100 Users
User Codes in Group 2 for Output 2 --- 10 Users
User Codes in Group 3 for Output 3 --- 10 Users

As the system comes with

function and the DURESS CODE is setting up by the system automatically with

the first digit of the User Code "+2". To prevent the other User Codes fall into the Duress Code, or the Duress
Codes fall into other User Codes, the first digit of a "

" User code "+2" or "-2" is not allowed for the later

User Code entry in programming. The system will refuse those code entries.

An User Code 56789 is saved in the system, then 36789 and 76789 are not allowed as other User
Codes.

Multi-Users

DURESS

Saved

For example:

The Factory Set Master Code

Summary of Contents for DK-9680 Series

Page 1: ...controlled by output 1 The circuit is open when the door is open It initiates the following functions 1 When the door is FORCED OPEN the door is opened without the use of a valid code or the EGRESS b...

Page 2: ...T CCESS TO ROGRAMMING 3 STATUS 1 In programming mode 2 Successful key entry 3 Successful code entry 4 Unsuccessful code entry 5 DAP jumper not replaced 6 Standby mode TONES 1 Beep 2 Beeps 5 Beeps Cont...

Page 3: ...ary Mode 601 Output 3 is 1 Second Momentary Mode 70 After 10 Successive False Code The Keypad Locks During 30 Seconds 80 Door Force Open Alarm Detection is Disabled 90 The Door Open Too long Timer is...

Page 4: ...rm enabled k Set the allowable time for door left open for 60 seconds before triggering of the door Open Too Long alarm A SINGLE USER MODE OPERATION An Example 1 Re uirement 8 2 Programming NOTE a Pre...

Page 5: ...door that is equipped with and leave it open for more than 60 seconds the programmed time The alarm starts Close the door the alarm stops automatically This feature reminds the owner to close the door...

Page 6: ...ted Code is Output 3 starts Output 3 stops Output 3 starts Output 3 stops 0321 9270 22898 3289 1 3289 2 3289 3 31223 53221 92 9270 22 22898 User Codes of Group 1 The Corresponding Duress Codes 9270 92...

Page 7: ...the programming mode by press the key E DELETE USER MULTI USER MODE 1 2 3 13 CONNECTING THE REMOTE KEYPAD UNIT S TO THE MASTER UNIT THE TAMPER SWITCH OF THE REMOTE KEYPAD UNIT The basic DK 9680 DK 98...

Page 8: ...contacts Stands for Normally Closed the contact is closed circuit at normal status It is open circuit when activated Stands for Normally Open the contact is open circuit at normal status It is closed...