5
D) Configuration of Relay Outputs
E) Personal Safety
F) Door Forced-Open-Alarm & Visitor Announcing
G) Allowable Door-Left-Open Time for Door-Open-Too-Long Alarm
-- Installer Programming
-- Installer Programming
-- Installer Programming
-- Installer Programming
40
#
41
#
42
#
50
#
51
#
52
#
60
#
61
#
62
#
70
#
71
#
72
#
76
#
80
#
81
#
82
#
83
#
9
#
9
#
1 to 999
Output 1 in Momentary Mode from 1 to 999 seconds
Output 1 in Start/Stop Mode without accelerated code
Output 1 in Start/Stop Mode with accelerated code
1 to 999
Output 2 in Momentary Mode from 1 to 999 seconds
Output 2 in Start/Stop Mode without accelerated code
Output 2 in Start/Stop Mode with accelerated code
1 to 999
Output 3 in Momentary Mode from 1 to 999 seconds
Output 3 in Start/Stop Mode without accelerated code
Output 3 in Start/Stop Mode with accelerated code
After 10 successive false codes, the keypad locks during
30 seconds
After 10 successive false codes, the Duress Output
switches to ground
5 to 10
Selectable of 5 to 10 successive false codes, the keypad
locks during 15 minutes. The keypad can be reset to
release locking with the Master Code at any time during
the locking period
00
Disappearance of all the above securities
Door Forced-Open-Alarm detection is Disabled
Door Forced-Open-Alarm detection is Enabled
Visitor announcing chime is given if the User Code in Group 1 is not keyed in first
when the door is opened.
Visitor announcing chime is always given when the door is opened
0
The timer is Disabled. Allows the door an infinite time to open for
1 to 999
Allowable time from 1 to 999 seconds for door open before the
Door-Open-Too-Long alarm is triggered
Access Keys Code Duration
Access Keys Number of False Entry
Validation
Comments
Access Keys Validation Comments
Access Keys Code Duration Validation Comments
Validation Comments
6
H) Exit Programming Mode
The Default Values
*
Keypad exits programming mode and returns to normal operation
Single User Mode if it is your selection.
Output 2 is 1 Second Momentary Mode
601 --- Output 3 is 1 Second Momentary Mode
70 ----- After 10 Successive False Code, The Keypad Locks During 30 Seconds
80 ----- Door Force-Open-Alarm Detection is Disabled
90 ----- The Door Open-Too-long Timer is Disabled
The mode of
for each output only allow
User Code for each output, and it is fixed to 4
digits. This mode is prepared for those people DO NOT like to Press the
for code entry to activate the output.
They only press the 4 digits User Code, then, the specific output is activated. Each output has its own code.
SINGLE USER OR MULTI-USERS SELECTION
The keypad consists two sets of application software for owner's selection in user code programming. One is
"Single User Code for Each Output" and the other is "Multi-User Codes for Each Output".
The keypad has been set with a Master Code of "0000" and Multi User Mode with the following "Default Values" at
the factory. You do not require to make any operation mode change if your selection is Multi-User Mode. However,
You have to refresh the system to
0000
401 --- Output 1 is 1 Second Momentary Mode
501 ---
The Single User Code
Single User Code
ONE
!
!
!
Validation
Comments
#
#
The Multi-User Codes
Code Entry Limitation for Multi-User Codes
The mode of
is prepared for setting up a group of user codes for each output. The User Codes can be
4 to 8 digits. To activate the desired output, the user has to press the
key to confirm of code entry in the
operation of the Multi-User Code. The following are the number of User Codes available in each group:
User Codes in Group 1 for Output 1 --- 100 Users
User Codes in Group 2 for Output 2 --- 10 Users
User Codes in Group 3 for Output 3 --- 10 Users
As the system comes with
function and the DURESS CODE is setting up by the system automatically with
the first digit of the User Code "+2". To prevent the other User Codes fall into the Duress Code, or the Duress
Codes fall into other User Codes, the first digit of a "
" User code "+2" or "-2" is not allowed for the later
User Code entry in programming. The system will refuse those code entries.
An User Code 56789 is saved in the system, then 36789 and 76789 are not allowed as other User
Codes.
Multi-Users
DURESS
Saved
For example:
The Factory Set Master Code