2) Programming

NOTE:

3) Operate The Keypad

a)

b)

c)

d)

Example:

-- Set the above requirement into the keypad

a) **Enter the Multi User Mode Command Code "

may not be necessary if the keypad was

already in Multi User Mode.

b) In case of wrong entry during programming, cancel it with

key, or, wait 10 seconds, then re-try.

-- Taking the data programmed above and other features in default values as reference

To command output 1, enter any one of the User Codes in Group 1 and validate via the

key

To command Authorization Control, enter the Authorization Code and validate via the

key

The Personal Master Code is a Super User Code to command the relay output and also make operation

authorization control as like an authorization code for the keypad. This feature allows the owner to use
only one code to operate two functions. Enter the Personal Master Code and validate via

and the

corresponding function code.

The Accelerated Code is the First Two Digits of the User code(s). If the Relay Output has been programmed

in Start / Stop mode with Accelerated Code (Programming Option 42), it is possible to activate the Relay

Output with only the First Two Digits of the User Code(s). Deactivating of the Output always requires the

composition of the Complete User Code(s).

Output Relay has been re-programmed to Start / Stop Mode with Accelerated Code (Programming Option

42) with the Complete Code of 1st User Code in Group 1:

The Accelerated Code is:

2nd User Code in Group 1:

The Accelerated Code is:

0000 *

8901 #

0 3289 #

1 01 8321 #

1 02 11223 #

1 03 33221 #

2 1 6854 #

40 1 #

51 #

72 10 #

*

#

#

8321 #

11223 #

33221 #

#

6854 #

#

3289 #1

3289 #2

83 #

8321 #

11 #

11223 #

-------------------- System has been set in programming mode with the factory-set Master Code
-------------------- System has been set for Multi User Mode** (please see NOTE (a) below)

--------------- 3289 has been stored as the new Personal Master Code

Super User Code

------ 8321 has been stored as the 1st User Code for door open

--- 11223 has been stored as the 2nd User Code for door open
--- 33221 has been stored as the 3rd User Code for door open

---------- 6854 has been stored as Authorization Code for inhibit control

---------------------- Output Relay has been set to Momentary Mode, 1 second for door strike

--------------------------- Inhibit Authorization Control in Start / Stop Mode

------------------ The keypad has been set to lock during 15 minutes after 10 successive false

codes

------------------------------------ Keypad exits programming mode. All the above data are stored and ready for

use

------ Output Relay activates for 1 second

--- Output Relay activates for 1 second
--- Output Relay activates for 1 second

------ Authorization Control Start / Stop

--- Output Relay activates for 1 second
--- Authorization Control Start / Stop (if programmed)

------------- Output Relay starts

------ Output Relay stops

------------- Output Relay starts

--- Output Relay stops

&

8901"

8321

83

11223

11

10

TONES

- - -

- - -

1 Beep
2 Beeps
5 Beeps
Continuous Beeps

1 second Long Beep

LED SIGNALS

ON
1 Flash
2 Flashes
5 Flashes
Continuous Flashes
1 Flash in 2 seconds interval

- - -

STATUS

1. In programming mode
2. Successful key entry
3. Successful code entry
4. Unsuccessful code entry
5. DAP jumper not replaced
6. In standby mode
7. Output relay activated

THE LED INDICATORS

THE PACIFIER TONES & THE LED INDICATING SIGNALS

THE DAP JUMPER D

A

P

RED

AMBER

GREEN

(INHIBIT)

(MAINS)

(DOOR)

It lights up if the operation of output relay is inhibited. Please see "Door Lock Inhibit Authorization" for more

details.

This is a status indicator. Its signal is in synchronization with the pacifier tones from the built-in buzzer.

It lights up during the time that output relay is active.

The built-in buzzer and the amber LED indicator give the following tones and signals for operation status:

All Pacifier Tones can be enabled or disabled through programming options at Location 83.
The Output Activation Beep can be enabled or disabled through programming options at Location 81.

If the Personal Master Code is forgotten, use the DAP jumper to override the forgotten code permitting the keypad

direct entry into programming mode. You are required to apply the following procedures precisely.

Disconnect power supply.
Displace the DAP jumper from OFF to ON position.
Reconnect power supply (buzzer is activated).
Put the DAP jumper back to OFF position (this done, the buzzer is de-activated).
The keypad is in programming mode and ready to receive new programming data.
As the old master code was forgotten, suggest you to put a 4 digit new master code into Location 0 first.
Enter the new programming data starting from Section (B) in the summary chart shown below.

Please

see the Chart below for the indication details.

NOTE:

*

1.
2.
3.
4.
5.
6.
7.

**

( IRECT CCESS TO ROGRAMMING)

THE FACTORY-SET MASTER CODE

--

IMPORTANT NOTE

For the owner's convenience in programming at the first time, the factory has put a Master Code 0000 into the

keypad. To compromise security, in all cases, the owner should program a Personal Master Code to invalidate the

factory-set Master Code before use.