6
11
RECORD A SUPER USER CODE ( Location 4)
The Super User Code is prepared for the owner to simply use it to operate the three outputs of the
system and to effect the prohibit function for Output 1.
SUPER USER CODE
The Super User Code has TWO functions. It can operate the three outputs or make inhibition to the
User Codes for the Output 1.
The Super User Code can be 4 to 8 digits.
When a new Super User Code is keyed in and confirmed, the old Super User Code is erased.
To delete the Super User Code from memory ---
4 #
OPERATION AND FUNCTIONS OF THE SUPER USER CODE
1) Operate Output 1, 2 and 3
The operation of the Super User Code is just like a normal User Code Plus a specific output
number.
---------- Output 1 Activates (Channel 1 Transmits)
---------- Output 2 Activates (Channel 2 Transmits)
---------- Output 3 Activates (Channel 3 Transmits)
2) Inhibit The User Codes For Output 1
The Super User Code can be used to inhibit the User Codes for the Output 1. It enhances the
security level of the access control system, such as stop the keypad after office hour or while the
house is nobody inside. Once the User Codes for Output 1 is inhibited, they become invalid. The
inhibit function is toggled in Start / Stop mode. The User Codes resume valid when the Super User
Code with the specific command number 9 is keyed-in again.
---------- All User Codes in Group 1 Disabled or Enabled in Toggle
NOTE:
The above inhibition only applies to the User Codes and the Visitor Codes for output 1 but
does not affect the operation of Output 1, 2 and 3 with Super User Code.
4 to 8 Digits
MASTER CODE
VALIDATION
LOCATION
4
#
SUPER USER PIN
SUPER USER PIN
SUPER USER PIN
SUPER USER PIN
#
1
#
2
#
3
#
9
POWER UP THE KEYPAD
After snapping the 9V battery on the battery clip, the keypad is in the power up delay of one minute
and the keypad gives beep sound during the period. It goes to normal operation after the time expired.
The power up delay allows the keypad circuit to stabilize and it is also the only time for the keypad to
accept the DAP code for setting it into programming mode in case of the Master Code is forgotten.
See the programming option “Direct Access to Programming Mode with “DAP” Code – 8 0 8 0” for the
details.
Battery Low Indication :
The keypad checks the battery each time when it is used. The keypad will generate continuous
warning beeps for 10 seconds when low battery is detected. Replace with new battery immediately.
LEARN THE KEYPAD ID
It is necessary to register the keypad with the receiver prior to use. The receiver can be the DA-2311,
AD-2322, or the DA-2800 from our company.
DELETE A KEYPAD OR A KEYFOB
If a keypad or a keyfob is lost it is necessary to delete it from the receiver. Every time the receiver will
clear all the keypad & keyfob IDs from its memory. Re-learning of the existing keypads / keyfobs are
required.
Press and hold the
LEARN
button on the receiver unit (It is equipped on the main circuit board
of the receiver) for 1 second until the
STATUS
LED turns ON.
The receiver is in a Waiting Period of 10 Seconds after the Status LED turning ON. It is waiting
for the keypad to send out its ID.
Press the
BELL
sign button on the keypad once within the waiting period. The keypad will send
out its ID immediately for the receiver to learn.
If your keypad already programmed with User Code(s), key in one of the user codes can also
achieve the learning of the keypad ID by the receiver.
The Status LED in the receiver turns OFF after the ID is learned.
Repeat the above learning procedures 1-4 for other keypads and/or remote keyfobs that are
used with the receiver. Total 40 keypads or keyfobs are allowed.
Press and hold the
LEARN
button for 8 seconds (The Status LED turns ON) until the LED gives
2 flashes to confirm that all the IDs are erased. After that, the LED turns OFF.
Record the new keypad and those not lost keyfobs again one by one with the procedures states
in the above section “Learn The Keypad ID”.
1)
2)
3)
4)
5)
1)
2)