Aegislink S-RF500 User Manual Download Page 2

 

S-RF500 

Buzzer   

Test/Silence Button 

LED Indicator 

Pinhole Pairing Button 

 

Package Contents 

 

1 × Alarm Unit   

1 × Mounting Bracket   

2 × Screws 

2 × Anchor Plugs 

1 × User Manual 

1 × Pin 

 

Summary of Contents for S-RF500

Page 1: ...r manual fully before installing and operating the alarm If you are installing this smoke alarm for use by others you must leave this manual or a copy of it with the end user Introduction Thank you fo...

Page 2: ...S RF500 Buzzer Test Silence Button LED Indicator Pinhole Pairing Button Package Contents 1 Alarm Unit 1 Mounting Bracket 2 Screws 2 Anchor Plugs 1 User Manual 1 Pin...

Page 3: ...CK YOUR HOME FOR A POTENTIAL PROBLEM AFTER ANY ALARM FAILURE TO DO SO CAN RESULT IN INJURY OR DEATH 3 TEST THIS SMOKE ALARM ONCE A WEEK IF THE ALARM EVER FAILS TO TEST CORRECTLY REPLACE IT IMMEDIATELY...

Page 4: ...button on the other unit until it beeps once and its LED flashes red rapidly as it is searching for a unit to connect to 3 After the search is successful and an interconnected group is created both u...

Page 5: ...iring mode to enter normal status 2 Test all wireless alarms to ensure they are interconnected before installation 3 A maximum of 24 wireless alarms can be interconnected on the same network 4 The mod...

Page 6: ...st and give an audible signal After testing the alarm will automatically enter standby mode The initiating unit will beep continuously with the LED flashing red Other interconnected units in the netwo...

Page 7: ...sleeping areas In a home with several bedrooms install an alarm in every bedroom If you install only one smoke alarm in your home install the alarm near to all bedrooms where possible and not in a ba...

Page 8: ...rms should be installed in the same room 7 When the wall or ceiling is angled the alarm needs to be installed within 3 feet 90 cm of the highest wall or ceiling point measured horizontally in the room...

Page 9: ...es of wire 2 Near fluorescent lights amateur radios electrical equipment or other devices that may transmit an RF signal as electronic noise may cause nuisance alarms WARNING 1 THIS ALARM SHOULD BE IN...

Page 10: ...re with their communication 1 Use the mounting bracket to mark the screw holes on the ceiling or the wall 2 Drill holes at the 2 marks using an appropriately sized drill bit Insert the anchor plugs an...

Page 11: ...econds 3 quick beeps every 4 seconds Dangerous smoke concentration is detected Open nearby windows and doors and immediately move to fresh air All other interconnected units in the network The LED fla...

Page 12: ...larms in the network Silence Mode Red LED flashes once every 5 seconds None After 9 minutes the unit will exit silence mode Low Battery Red LED flashes once every 60 seconds 1 beep every 60 seconds Ea...

Page 13: ...ay function that extends the wireless interconnected network for wide detection coverage Silence Mode If you press the silence button during an alarm state the unit will be in the silence mode for 9 m...

Page 14: ...d indicator are working properly by testing the unit once a week 2 As a minimum your smoke alarm should be cleaned once every 3 months Remove the unit from the ceiling and clean the alarm cover and ve...

Page 15: ...s signal might be blocked or out of range False alarms triggered intermittently or when residents are cooking taking showers etc Check the location of your smoke alarm see Installation Positioning Cle...

Page 16: ...equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the e...

Reviews: