22
GB
STARTING THE CHARGING
PROCESS
As soon as the charger is connected
properly, the charging process starts
automatically.
6 / 12 / 24 V VOLTAGE
SELECTION SWITCH
The 6 Volt / 12 Volt / 24 Volt
selector switch allows you to charge
6 Volt, 12 Volt or 24 Volt batteries.
The voltage of the battery that you
want to charge must correspond to
the battery charger’s voltage: only
then can the charger be connected to
the battery. Connecting the battery to
the charger when the voltages do not
match will cause battery damage.
Check the battery voltage before
starting the charging process. 3-cell
batteries typically have a nominal
voltage of 6 V. 6-cell batteries typi-
cally have a nominal voltage of 12
V. 12-cell batteries typically have a
nominal voltage of 24 V.
CURRENT SELECTOR SWITCH
Set the current selector switch so that
the charging current is compatible for
the battery you want to charge. The
following recommended minimum
battery capacities „C“ should not be
underrun (recommended values).
Maximum charging current (Amp
RMS) – recommended battery capa-
city:
BATTERY 6 V
Amp
C (AH)
Setting
1
1
< 10
2
4
< 40
3
9
< 90
4
21
< 200
5
33
< 330
6
60
< 620
BATTERY 12 V
Amp
C (AH)
Setting
1
2
< 20
2
6
< 60
3
12
< 120
4
22
< 220
5
33
< 330
6
60
< 620
BATTERY 24 V
Amp
C (AH)
Setting
1
4
< 40
2
9
< 90
3
14
< 140
4
18
< 190
5
26
< 260
6
45
< 500
OPERATING MODE SELECTOR
Prior to starting any charging
process, make sure to set the proper
charging voltage for your battery.
Set the operating mode switch to the
desired position before starting the
charging process.