4.
If necessary, clean the filter with a
vacuum cleaner. Close the filter.
5.
If necessary, remove fluff from the
filter socket and gasket. You can use
a vacuum cleaner. Place the filter
back inside the filter socket.
15.2
Emptying the water
container
Empty the condensed water container
after each drying cycle.
If the condensed water container is full,
the programme stops automatically. The
message
Water Tank Warning
comes
on the display and you must empty the
water container.
To empty the water container:
1.
Pull the water container out keeping
it in a horizontal position.
2.
Pull the plastic connection out and
drain the water into a basin or
equivalent receptacle.
3.
Push the plastic connection back in
and place the water container back
into position.
4.
To continue the programme press
the Start/Pause button.
15.3
Cleaning the condenser
If the message
Clean the heat
exchanger area
comes on the display,
inspect the condenser and its
compartment. If it is dirty, clean it. Do
the check not less than once a 6 months.
WARNING!
Do not touch the metal
surface with bare hands. Risk
of injury. Wear protective
gloves. Clean carefully to
avoid damaging the metal
surface.
To inspect:
1.
Open the door. Pull the filter up.
2.
Open the condenser cover.
3.
Turn the lever to unlock the
condenser lid.
www.aeg.com