17
Installation
The mains cable may only be changed by a qualified electrician or
competent person. If your appliance needs repairing, please contact
your local AEG Service Force Centre.
Electrical Connection
Any electrical work required to install this appliance should be carried
out by a qualified electrician or competent person.
WARNING – THIS APPLIANCE MUST BE EARTHED
The manufacturer declines any liability should these safety mea-
sures not be observed.
Before switching on, make sure the electricity supply voltage is the
same as that indicated on the appliance rating plate. The rating plate
is inside, on the
right.
The appliance is supplied with a 13 amp plug fitted. In the event of
having to change the fuse in the plug supplied, a 13 amp ASTA
approved (BS 1362) fuse must be used.
Important
The wires in the mains lead are coloured in
accordance with the
following code:
Green and Yellow Earth
Blue
Neutral
Brown
Live
As the colours of the wires in the mains lead
of this appliance may not correspond with the coloured markings
identifying the terminals in your plug, proceed as follows:
1.The wire coloured green and yellow must be connected to the termi-
nal marked with the letter “E” or by the earth symbol
or coloured
green and yellow.
2.The wire coloured blue must be connected to the terminal marked
“N” or coloured black.
3.The wire coloured brown must be connected to the terminal marked
“L” or coloured red.
4.Upon completion there must be no cut, or stray strands of wire pre-
sent and the cord clamp must be secure over the outer sheath.
Warning!
A cut-off plug inserted into a 13 amp socket is a serious
safety (shock) hazard. Ensure that the cut-off plug is disposed of safe-
ty.
207
GREEN & YELLOW
13 AMP. FUSE
BROWN
CORD CLAMP
BLUE
13 AMP