Output: Connect ground cable (PE) to ground screw of chassis first;
Short terminal N/N with busbar #1, connect AC cable(N);
Short terminal L1/L2/L3 with busbar #3, connect AC cable(L).
Mo
de 1-1(single source)
Input:
Connect
ground cable (PE) to ground screw of chassis first;
Short terminal N/N with busbar #1, connect AC cable(N);
Short terminal mL1/bL1/mL2/bL2/mL3/bL3 with busbar #6, connect AC
cable(L).
Output: Connect ground cable (PE) to ground screw of chassis first;
Short terminal N/N with busbar #1, connect AC cable(N);
Short terminal L1/L2/L3 with busbar #3, connect AC cable(L).
Mode 1-1(dual source)
Input: Connect ground cable (PE) to ground screw of chassis first;
Short terminal N/N with busbar #1, connect AC main source cable(N) and
bypass source cable(N);
Summary of Contents for PROTECT 1 LCD
Page 5: ...Revision Change Date Name 00 Created 21 07 2021 AN ...
Page 6: ......
Page 32: ... Connect with user s own EBM Connect user s own EBM to UPS with Battery cable if configured ...
Page 37: ... 3 3 configuration dual source 3 1 configuration single source ...
Page 38: ... 3 1 configuration dual source 1 1 configuration single source ...
Page 40: ...Note Note Note Note Common battery configuration is not suitable for standard model ...