5
English
EXTENSION CORD CABLE SIzE
Refer to the table below to ensure the cable size of the extension cords you use are capable of carrying the required load.
Inadequate size cables can cause a voltage drop, which can burn out the appliance and overheat the cord.
Current in
Amperes
Load in Watts
Maximum Allowable Cord Length
At 230V
#8 Wire
#10 Wire
#12 Wire
#14 Wire
#16 Wire
2.5
575
305 m
183 m
114 m
76 m
5
1150
152 m
91 m
61 m
38 m
7.5
1725
107 m
61 m
38 m
30 m
10
2300
76 m
46 m
30 m
15 m
15
3450
46 m
30 m
20 m
20
4600
53 m
38 m
22 m
25
5750
46 m
30 m
30
6900
38 m
20 m
40
9200
27 m
ELECTRIC MOTOR LOADS
It is characteristic of common electric motors in normal operation to draw up to six times their running current while starting. This
table may be used to estimate the watts required to start “Code G” electric motors; however, if an electric motor fails to start or
reach running speed, turn off the appliance or tool immediately to avoid equipment damage. Always check the requirements of
the tool or appliance being used compared to the rated output of the generator.
Motor Size (H.P.)
Running Watts
Watts Required to Start Motor
Repulsion Induction
Capacitor
Split Phase
1/8
275
600
850
1200
1/6
275
600
850
2050
1/4
400
850
1050
2400
1/3
450
975
1350
2700
1/2
600
1300
1800
3600
3/4
850
1900
2600
—
1
1100
2500
3300
—
ELECTRICAL
Summary of Contents for Powertools AGN5000DEB
Page 1: ...Original Instructions AGN5000DEB DIESEL PORTABLE GENERATOR ...
Page 18: ...14 English WIRING DIAGRAM AGN5000DEB ...
Page 19: ......