Reset Button 

Press the Reset button continuously for 5 sec. to load factory defaults: Use a pointed object, such as a 
straightened paper clip or toothpick, to press the reset button. This will cause the Ready LED to blink on 
and off. The factory defaults will be loaded once the Ready LED stops blinking (after about 5 seconds) 
At this point, you should release the reset button. 

Factory default settings include an active password protection. The factory default password is “moxa”. 

LED Indicators  

The Ethernet converter has three LED indicators, which are described in the following table. 

LED Name 

LED Color  LED Function 

Ready 

Red 

Steady on: Power is on and Ethernet converter is booting up. 
Blinking: Indicates an IP conflict, or DHCP or BOOTP server 
is not responding proberly.  

Green 

Steady on: Power is on and Ethernet converter functioning 
normally.  
Blinking: The Ethernet converter has been located by Admin-
istrator´s Location function. 

 

Off 

Power is off, or power error condition exists. 

Link 

Orange 

10 Mbps Ethernet connction. 

Green 

100 Mbps Ethernet connction. 

Off 

Ethernet cable is disconnected, or has a short. 

Tx/Rx 

Orange 

Serial port is receiving data. 

Green 

Serial port is transmitting data. 

Off 

No data is being transmitted or received though the serial port 

 

 

 

 

 

Summary of Contents for NPort 5110

Page 1: ...Ethernet Converter Quick Installation Guide for Ethernet RS232 NPort 5110 ...

Page 2: ...vice server verify that the package con tains the following items Ethernet NPort 5110 series 1 port serial device server Documentation and software CD Quick Installation Guide 3 Hardware Introduction As shown in the following figures Ethernet converter has one lumberg male connector for power and RS232 serial data Connector Typ Lumberg RSF 5B Connector Power Serial Port Reset button RJ45 10 100M E...

Page 3: ...LED indicators which are described in the following table LED Name LED Color LED Function Ready Red Steady on Power is on and Ethernet converter is booting up Blinking Indicates an IP conflict or DHCP or BOOTP server is not responding proberly Green Steady on Power is on and Ethernet converter functioning normally Blinking The Ethernet converter has been located by Admin istrator s Location functi...

Page 4: ... serial port The reader has to be supplied with 12 to 30V DC The maximum output power of the power supply has to be 1 2 Watt Be sure that you use the right polarity Connector Typ Lumberg 0976 PFC 101 Power supply Pin1 12 30 Volt Pin4 GND Data interface Pin2 RXD readers data input Pin3 TXD readers data output Pin5 GND 1 2 A B ...

Page 5: ...to your computer s Ethernet port In this case use a cross over Ethernet cable Step 3 Connect the Ethernet NPort5110 device server s serial port to a serial device Step 4 Placement options tophat rail Software Installation Information To install NPort Administration Suite insert NPort Document Software CD into your computer s CD Rom driver Once the NPort Installation CD windows opens click on the I...

Page 6: ...d model Operating Humidity 5 to 95 RH Dimensions 130mm x 60mm x 40mm 130mm x 80mm x 40mm with tophat rail Serial Line Protection 15KV ESD for serial port Magnetic Isolation 1 5KV for Ethernet Power Line Protection Level 2 Burst EFT EN61000 4 4 Level 2 Surge EN61000 4 5 Password moxa Revisions 22 01 13 Revision 00 Initial edition MM 02 05 18 Revision 01 Password moxa ...