Installation - for contractors
INSTALLATION
7.
Safety
Only a qualified contractor should carry out installation,
commissioning, maintenance and repair of the appliance.
7.1
General safety instructions
We guarantee trouble-free function and operational relia-
bility only if original accessories and spare parts intended
for the appliance are used.
!
Material losses
Observe the max. permissible inlet temperature.
Higher temperatures may damage the appliance.
You
can limit the inlet temperature by means of a central
thermostatic valve
.
7.2
Instructions, standards and regulations
Note
Observe all applicable national and regional regula
-
tions and instructions.
The specific electrical resistance of the water must not fall
below that stated on the type plate. In a linked water net-
work, factor in the lowest electrical resistance of the water
(see chapter "Specification / Data table").
Your water sup-
ply utility will advise you of the specific electrical water
resistance or conductivity.
8.
Appliance description
8.1
Standard delivery
The following are delivered with the appliance:
◦
Sieve inside the cold water inlet
◦
Special aerator "SR"
◦
Connection hose 3/8, 500 mm long, with gaskets*
◦
Tee 3/8*
◦
Company logo for oversink installation
◦
*for the connection as pressure-tested appliance
8.2 Accessories
Special aerator "SR"*
◦
SR 3: Part number 289591
for MTE 350 and MTE 440
◦
SR 5: Part number 270582
for MTE 570 and MTE 650
* For use in thread M22/M24.
Non-pressurised taps
◦
AHS 50
Sensor tap for washbasins
◦
AHo 40 MTH
Wall mounted tap for oversink
installation
◦
AHu 40 MTH
Twin lever basin tap
◦
AHEu 40 MTH Mono lever basin tap
Pressure-tested tap
◦
ADS 40
Sensor tap for washbasins