Downloaded from www.vandenborre.be
Machine settings
Setting
Implementation
Buzzer permanent
on/off
1. Turn the programme selector to any programme.
2. Press simultaneously the DELICATE (DELICAAT) and BUZZER (ZOEMER)
buttons and hold down for approx. 5 seconds.
– diode above BUZZER (ZOEMER) button starts lighting - buzzer per
-
manently on.
– lighting diode comes off - buzzer permanently off.
3. The buzzer is by default always off. You can use the BUZZER (ZOEMER)
button to activate or deactivate sound but the machine does not
memorize your selection.
Water hardness
1)
1. Turn the programme selector to any programme.
2. Press simultaneously the DELICATE (DELICAAT) and START PAUSE
(START PAUZE) buttons and hold down for approx. 5 seconds. The
current setting is shown by the following red diodes:
– WATER RESERVOIR (TANK) diode on - high conductivity >600
μ
S/
cm
– FILTERS (ZEEF) diode on - medium conductivity 300-600
μ
S/cm
– CONDENSER (WARMTEWISSELAAR) diode on - low conductivity
<300
μ
S/cm
3. Press the START PAUSE (START PAUZE) button sequentially until you
set desired level.
4. To memorize setting press simultaneously the DELICATE (DELICAAT)
and START PAUSE (START PAUZE) buttons or turn knob to OFF (UIT)
position
Emptying water res-
ervoir
-
warning LED
off
2)
1. Turn the programme selector to any programme.
2. Press simultaneously the BUZZER (ZOEMER) and DELAY START (STAR
-
TUITSTEL) buttons and hold down for approx. 5 seconds.
The current setting is shown by the following red diode:
– WATER RESERVOIR (TANK) diode flashes - diode warning is per
-
manently off
– WATER RESERVOIR (TANK) diode steady - diode warning is activa
-
ted
1)
Water contains, a variable quantity of limestone and mineral salts of which quantities vary according to
geographical locations thus varying its conductivity values. Relevant variations of the conductivity of the water
compared to those prefixed by the factory could slightly influence the residual humidity of the laundry at the
end of the cycle. Your dryer allows you to regulate the sensitivity of the drying sensor based on conductivity
values of the water.
2)
By default the warning LED is always on at the end of the drying cycle or during the cycle if the water reservoir
is full. When using an external drain for the condensed water warning can be off
Technical data
82
Machine settings