Directly into a
drain pipe at a
height
of not less
than 60 cm and
not more than
90 cm.
The end of the
drain hose must always be
ventilated
, i.e. the inside diameter of the
drain pipe must be larger than the outside diameter of the drain hose.
The drain hose must not be kinked. Run it along the floor; only the part
near the drainage point must be raised.
Electrical connection
This machine is designed to operate on a 220-230 V, single-phase,
50 Hz supply.
Check that your domestic electrical installation can take the maximum
load required (2.2 kW), also taking into account any other appliances in
use.
Connect the machine to an earthed socket.
The manufacturer declines any responsibility for damage or injury
through failure to comply with the above safety precaution.
Permanent connection
In the case of a permanent connection it is necessary that you install a
double pole switch between the appliance and the electricity supply
(mains), with a minimum gap of 3 mm between the switch contacts and
of a type suitable for the required load in compliance with the current
electrical regulations.
The switch must not break the yellow and green earth cable at any
point.
This operation has only to be performed by a qualified electrician.