37
ENGLISH
step
action
11
Connect the cold water.
–
Connect the cold water inlet of the tap (8) to the t-piece (14) (see
image 22). NOTICE! The cold water inlet of the tap (8) is the blue
woven hose.
12
Connect the warm water.
If you install the solo configuration:
–
Connect the warm water inlet of the tap (9) to the warm water
supply (see image 23). NOTICE! The warm water inlet of the tap
(9) is the red woven hose.
If you install the combi configuration:
–
Connect the warm water inlet of the tap (9) to the warm water
outlet of the mixing valve (29) (see image 24). NOTICE! The warm
water inlet of the tap (9) is the red woven hose. The warm water
outlet of the mixing valve (29) is indicated with “MIX”.
4.4 Filling the appliance with water
CaUTION!
Do not insert the plug of the boiler into the earthed AC wall
socket! First fill the system with cold water according to the instructions in
this section.
To fill the appliance with cold water:
step
action
1
Make sure all connections are tightened properly to prevent leakages.
2
Make sure water can drip freely from the pressure-relief device (22).
3
If the mixing valve is (D) installed, set the temperature with the
temperature regulator (34).
4
Make sure the valve (16) on the pressure safety valve is in the OPEN
position.
5
Open the cold water supply valve.
6
If present, open the warm water supply valve.
7
Check all connections for water tightness.
8
Push and hold the button on the boiling water handle (11). Turn the
handle counterclockwise to open the valve. Keep the valve open until a
constant flow of water flows out the spout.
9
Move the mixer handle (12) to the right to open the valve. Keep the
valve open until a constant flow of water flows out the spout. The
system is now fully filled with water.
Summary of Contents for GYB00416DT
Page 2: ......
Page 5: ...3 36 37 38 39 41 40 42 29 31 30 34 27 28 32 33 35 ImagEs BIllEDEr ...
Page 6: ...4 www aeg com 3 Before installation 3 Før installation ...
Page 7: ...5 4 Overview Solo Situation 4 Overblik over enkelt konfiguration ImagEs BIllEDEr ...
Page 8: ...6 www aeg com 5 Overview Combi Situation 5 Overblik over kombineret konfiguration ...
Page 9: ...7 6 The tap Installed 6 Hanen installeret ImagEs BIllEDEr ...
Page 10: ...8 www aeg com 7 The filter installed optional 7 Filteret installeret valgfrit ...
Page 24: ...22 www aeg com 25 Use boiling water handle 25 Brug af håndtag til kogende vand PUSH 1 2 ...
Page 27: ...25 141 138 236 393 168 236 393 168 442 126 106 ImagEs BIllEDEr ...