1. Operating instructions
1.1 Description of device
The charging controller ELFAMATIC µC 3000 continuously calculates the correct amount of thermal
energy stored in the storage heater.
The outside temperature trend and the tariff information from the power supply company are
taken into consideration.
The ELFAMATIC µC 3000 has a backlit LCD.
In normal operating mode, the time (or the operating time if autosynchronisation is deactivated),
the temperature measured by the outside temperature sensor and all operating states (by pressing
the individual buttons) are displayed on the LCD.
In normal operating mode, the backlight is switched off but is switched on again as soon as one of
the buttons M, P, + or - is pressed. It switches off again after 10 seconds if no button is pressed.
LCD:
1
Active parameter
2
Current parameter value
3
Status display VR / LF / LZ / KU
4
Status display ED / SH / SYN
M
P
+
–
Select menu
Select parameter
Change parameter
Buttons:
M
P
+
—
ELFAMATIC µC 3000
1
3
2
4
Status displays
(bar indicators underline ...):
VR
at terminal VR mains voltage is applied (230 V power supply utility signal)
LF
at terminal LF mains voltage is applied (230 V power supply utility signal)
LZ
at terminal LZ mains voltage is applied (230 V power supply utility signal)
KU
at terminal KU mains voltage is applied (depression is activated)
ED
at terminal Z1 the emitted control signal is applied (230 V control voltage)
SH
at terminal SH the signal for triggering the heating contactors is applied (230 V)
SYN
automatic operation time synchronization
(timeout
Ö
LF or LZ is continuously applied)