For the User
Brief instructions – for rapid programming
If all of the following requirements are met, the device can be put into operation in the way
described below.
– Storage heater system with control voltage system 80 % ED
– Use of the supplied or an existing DIN atmospheric sensor
– Charging model is provided in the table on page 8–10.
Setting time
LCD
Button
+
or
–
Press
This display appears when the device is put into
operation of the first time or following a power failure
which lasted longer than approx. 6 hours.
If the time is not set, the ELFAMATIC µC 3000
automatically operates as a
forward controller.
Charging is performed in all cases.
Button
Press
Note
VR LF LZ KU
ED
SH
SYN
00:00
00:00
VR LF LZ KU
ED
SH
SYN
14:51
P
The time is stored.
If no button is pressed after the time has been set, the
UHR (time) parameter remains active for 15 minutes (the
clock continues to run) and is stored automatically when
the 15 minutes have elapsed.
M
Setting charging model
LCD
Button
+
or
–
Press
Select the desired charging model from the „Charging
model“ table (see page 8–10) and enter the code
number.
Button
Press for
approx.
3 sec.
Note
VR LF LZ KU
ED
SH
SYN
INST
M
VR LF LZ KU
ED
SH
SYN
LM
1
Press
P
VR LF LZ KU
ED
SH
SYN
LM
28
If no button is pressed for 15 minutes, the display
automatically returns to the default display (time and
outside temperature are shown alternately).
Press
4x
M
VR LF LZ KU
ED
SH
SYN
14:53
14:53
All necessary entries have now been made.
The controller now operates using all parameters for the specific charging model.