6.2.3 Selecting the operating mode
Pressing the „M“ key repeatedly allows you to select
the operating mode you require.
The operating modes are activated in the following
order:
Once 30“ has elapsed since the „M“ key was last pus-
hed, the operating mode activation sequence begins
from the beginning again, to make it quicker to switch
from any mode to Comfort mode.
Icon
Description
When used
Comfort
When at home. The radiator works to maintain the comfort temperature set.
Eco
When you are away from home for short periods (from 2 to 48 hours) or you
are sleeping. The radiator works to maintain the eco temperature set and save
energy.
Anti-freeze
When you are away from home for long periods (more than 48 hours). The
temperature is automatically set at 7±3°C and cannot be changed.
Program 1
When you want preset programmed operation, suitable for those that do not
work from home. THIS PROGRAM CAN ALSO BE CUSTOMIZED FOLLOWING THE
INSTRUCTIONS LISTED IN PARAGRAPH 6.2.6.
Program P2
When you want preset programmed operation, suitable for holiday homes
used at the weekend.
Program P3
When you want preset programmed operation, suitable for offices and work-
places.
Pilot wire
When checking operation of the radiator, using an external control unit with
a pilot wire.
6.2.3.1 Description of preset programmes
Monday-Friday
Saturday-Sunday
Monday-Thursday
Friday
Saturday-Sunday
Monday-Friday
Saturday-Sunday
= temperature „COMFORT“
= temperature „ECO“
= temperature anti-freeze