1. Installation instructions

 

for the qualified installer

 

 

Unit  must  be i nstalled  in  a    

 

 

vertical  position  with  the  water 

fittings pointing downward.  Do not install 
unit where it would routinely be splashed 
with water.  Electric shock may result. 

1.4 Electrical connection

 

1. All electrical work must comply with 

 

  national and applicable state and 

 

  local electrical codes.

 

2. The Mini Multipoint should be 

 

  connected to a properly  grounded  

 

  dedicated branch circuit of proper   

 

  voltage rating.  In installation with 

 

  several Mini Multipoint units, each   

 

  unit requires an independent circuit. 

 

3. The “live” wires must be connected 

 

  to the slots on the terminal block 

 

  marked L.  The ground wire must be 

 

  connected to the slot marked with 

 

  the ground symbol.

 

4. Reinstall plastic cover.

 

 

Warning:

 

 

Before  begining  any  work  on 

the electric installation, be sure that main 
breaker panel switch is, “OFF” to avoid any 
danger  of  electric  shock.    All  mounting 
and plumbing must be completed before 
proceeding with electrical hook-up where 
required by local, state or national electrical 
codes the circuit should be equipped with 
a “Ground fault interrupter”.

1.5  Regulations and Provisions

-  Regulations of the local power supply    
  company should be observed.
-  Regulations of the water supply company  
  should observed
-  Technical data.
-  Install the unit flush with the wall.
-  Electrical connection to be secure.

-  The device must be capable of being  
  isolated from the mains, for example by  
  fuses, with an isolating distance of at    
  least 3 mm, in all poles.

 

 

The unit must be earthed (see 

 

 

circuitdiagram).   To protect  

against water penetration, the cable seal 
(3) must be used.

1.6 Important note

 

 

All  the  information  in  these    

 

 

Operating  and  Installation  

Instructions must be carefully followed. 
These instructions provide important details 
regarding the safety, operation, installation, 
and maintenance of the unit.

1.7 Installation location

 

 

The  unit is to be installed in    

 

 

a closed,  frost-free  room 

(disconnected units are to be  stored in a 
frost-free location, since there will always 
be some water left in the unit) The BMT  is 
to be installed vertically on a wall (hot 
water connection downwards).

 

 

Warning :

 

 

 

Open hot water faucet for a few 

minutes until water flow is continuous and 
all air is purged from water pipes.The unit’s 
plastic  cover  must  be  installed  before  the 
circuit breaker is turned on.

Summary of Contents for BMT 60

Page 1: ...WATER HEATER MODEL BMT 60 OPERATION AND INSTALLATION INSTRUCTIONS คู มือแนะนำ การใช งานและติดตั งเครื องทำ น ำ ร อน ...

Page 2: ...ance ข อมูลทั วไป เนื อหาส วนนี เกี ยวข องกับการใช งานซึ งจัดทำ ขึ นสำ หรับผู ใช และช างผู ชำ นาญงาน เนื อหาส วนนี เกี ยวข องกับการติดตั งซึ งจัดทำ ขึ น สำ หรับช างผู ชำ นาญงาน กรุณาอ านอย างละเอียด อ านคำ แนะนำ เหล านี อย างละเอียด ก อนการใช งานอุปกรณ และเก บคำ แนะนำ นี ไว สำ หรับการอ างอิงในอนาตค หากมีการ ส งต ออุปกรณ นี ให บุคคลที สาม กรุณาให คำ แนะนำ นี กับผู ใช คนใหม ด วย เครื องทำ น ำ ร อนนี...

Page 3: ...Fig 1 Fig 2 Fig 3 Fig 4 115 mm 50 mm min 4 5 mm max 5 5 mm 4 x 35 mm 6 mm 6 m m 3 1 Installation instructionsfor the qualified installer ...

Page 4: ...4 Fig 5 170 mm 80 mm 220 mm 1 Installation instructionsfor the qualified installer ...

Page 5: ...ctrically ground unit may result in serious injury or death L N Manual re set Thermal cut out The Position Tabel Selector Switch 4 Step Micro Switch Heating Elements Selector Switch 4 Step Lamp POSITION OFF MID LOW HIGH A B 1 2 3 4 A 3 2 B 5 1 Installation instructionsfor the qualified installer ...

Page 6: ...gh the unit The input of heat into the water is electronically controlled Please set the desired temperature using the knob on the front cover The LED lights up when the unit is ON 1 2 Detail description Fig 6 1 Fixing hole 2 nos 2 Cable seal 3 Step switch 4 Differential pressure switch assembly 5 Cold water connection 6 Hot water connection 7 Water container assembly 8 Thermostat 9 Filter 10 Unio...

Page 7: ...rcuit should be equipped with a Ground fault interrupter 1 5 Regulations and Provisions Regulations of the local power supply company should be observed Regulations of the water supply company should observed Technical data Install the unit flush with the wall Electrical connection to be secure The device must be capable of being isolated from the mains for example by fuses with an isolating dista...

Page 8: ... the user how the unitworks and familiarise him or her with its use Advise the user about possible hazards high water temperature Hand over these instructions to be kept in a safe place 1 9 Service note When carrying out any work isolate the unit from the mains andshutoffthewaterconnection Clean the filter Disconnect the union nut remove washer filter and clean Re assemble in reverse order 1 10 Wa...

Page 9: ... until temperature has stabilized 4 Check the water temperature with your hand and make sure that it does not feel too hot Reduce if necessary 5 Explain to the user how the unit works and familiarize him or her with its use Advise the user about possible hazards Hand over these instructions to be kept for future reference Warning Open hot water faucet for a few minutes until water flow is continuo...

Page 10: ... by a qualified installer The company does not accept liability for failure of any good supplied which have not been installed and operated in accordance with the manufacturer s instructions Fault Cause Rectification No hot water Circuit breaker off Safety thermal cut out tripped Turn circuit breaker on Reset thermal cut out Water not hot enough Water flow too high Voltage too low Reduce water flo...

Page 11: ...รูปที 1 รูปที 2 รูปที 3 รูปที 4 115 mm 50 mm min 4 5 mm max 5 5 mm 4 x 35 mm 6 mm 6 m m 11 1 คำ แนะนำ การติดตั งสำ หรับช างผู ชำ นาญงาน ...

Page 12: ...12 รูปที 5 170 mm 80 mm 220 mm 1 คำ แนะนำ การติดตั งสำ หรับช างผู ชำ นาญงาน ...

Page 13: ...to electrically ground unit may result in serious injury or death L N Manual re set Thermal cut out The Position Tabel Selector Switch 4 Step Micro Switch Heating Elements Selector Switch 4 Step Lamp POSITION OFF MID LOW HIGH A B 1 2 3 4 A 3 2 B 13 1 คำ แนะนำ การติดตั งสำ หรับช างผู ชำ นาญงาน ...

Page 14: ...Mini Multipoint ให ใกล กับหัวจ ายน ำ ร อนให มากที สุดเท าที จะทำ ได 2 เว นที ว างสำ หรับปฏิบัติงานบริเวณรอบด านไว อย างน อย 5 นิ ว 3 ถอดฝาพลาสติกครอบเครื องออก รูปที 3 4 ยึดตัวเครื องเข ากับผนังโดยไขสกรู 2 ตัวลงในรู ของพุกพลาสติกที อุดในรูกำ แพง ซึ งมาพร อมกับ เครื อง รูปที 4 จุดต อน ำ 1 งานระบบประปาทั งหมดจะต องสอดคล องกับ ระเบียบการประปาของพื นที และของเขตที มีผล บังคับใช ในประเทศ 2 ตรวจสอบให มั...

Page 15: ...ที ทำ ให น ำ ในถังต มเป นน ำ แข ง และต องติดตั งเครื องในแนวตั งเท านั น คำ เตือน ก อนการใช งานปกติ ต องเปิดวาล วน ำ ร อนให มาก ที สุด แล วปล อยน ำ ไหลผ านเครื องสักครู เพื อล างตะกอนสิ ง สกปรก และไล อากาศออกจากเครื อง และควรปิดฝาครอบ เครื องให เรียบร อยทุกครั งก อนเปิดเครื องใช งานปกติิ การส งมอบเครื องแก ผู ใช งาน อธิบายวิธีการใช งานอย างละเอียด และถูกต องแก ผู ใช งาน เตือนความเป นไปได ว าอาจเกิ...

Page 16: ... ไม มีน ำ ในเครื อง กิโลกรัม 1 4 การต อไฟฟ า 1 N PE 220 230 V ระดับการปรับการควบคุม ปรับได 4 ระดับ Off Low Med High กำ ลังไฟฟ า kW อัตราการไหลของกระแสไฟฟ า A kW A 220 V 6 0 27 3 230 V 6 6 28 7 ขนาดของเบรคเกอร ที แนะนำ A 30 ขนาดของสายไฟที แนะนำ Sqmm 6 0 การต อท อน ำ โดยใช การติดตั งภายนอก นิ ว G 1 คู มือแนะนำ การติดตั งสำ หรับช างผู ชำ นาญงาน ...

Page 17: ...ยกับการใช งานเครื อง แนะนำ ผู ใช ถึง อันตรายที อาจจะเกิดขึ นได ส งมอบคำ แนะนำ เหล านี ให เก บไว สำ หรับใช อ างอิงในอนาคต คำ เตือน ก อนการใช งานปกติ ต องเปิดวาล วน ำ ร อนให มาก ที สุด แล วปล อยน ำ ไหลผ านเครื องสักครู เพื อล างตะกอนสิ ง สกปรก และไล อากาศออกจากเครื อง และควรปิดฝาครอบ เครื องให เรียบร อยทุกครั งก อนเปิดเครื องใช งานปกติิ การบำ รุงรักษาตามปกติ เครื องทำ น ำ ร อน Mini Multipoint ได รับ...

Page 18: ...ดๆ สำ หรับสิ งที เกิดขึ นจากการไม ปฏิบัติตามคู มือ ข อขัดข อง น ำ ไม ร อน น ำ ร อนไม พอ สาเหตุ เบรกเกอร วงจรไฟฟ าปิดอยู อุปกรณ ตัดความร อนนิรภัยทำ งานอยู มีอัตราการไหลของน ำ มากเกินไป แรงดันไฟฟ าต ำ เกิน การแก ไข เปิดเบรกเกอร วงจรไฟฟ า ตั งค าอุปกรณ ตัดความร อนใหม ลดอัตราการไหลของน ำ จ ายแรงดันไฟฟ าที ถูกต องให กับ เครื อง 3 การรับประกัน 4 การแก ไขข อขัดข อง สำ หรับผู ใช งาน ...

Page 19: ...19 ...

Page 20: ...SIZE A5 MATERIAL GREEN READ PAPER 75 G PLASTIC BAG 7 x 11 INCH PART NO 7901 281912 PART NAME MANUAL BMT 60 TH EN REV 04 Product code BMT 60 1121 227256 ...

Reviews: