6
ENGLISH
HS 40, HS 50, HS 60, HS 70
Leaf hedges: June and October.
Pine hedges: April and August.
Fast growing hedges: from May every 6 weeks.
Always keep the machine in the storage
sheath. The storage sheath can also be
mounted on a wall.
Never clean the machine with water.
After cutting resin-containing hedges clean blades with a resin solvent spray.
Always disconnect the plug from the socket before carrying out any work on the
machine.
Should the blades become blunt or damaged they can be exchanged for a set of
new ones. Dismantle blade assembly as stated below and send it to the AEG
Service Centre.
Before changing the blade assembly, make sure that blades are in a symmetrical
position. If not, let the machine run again.
The change of blades can be effected with the protection sheath in place. This
prevents injuries and keeps the hands clean.
1.
Turn machine around, the underside
pointing upwards.
2.
Remove 6 screws (A) and the gearbox lid
(B).
To loosen the screws, only use Torx
screwdrivers.
3.
Undo the two locking screws (C).
4.
Pull out the blade assembly (D).
5.
The assembly is done in reverse order.
Observe that the heart shaped profiles of
the eccentric drive (E) and the driving
sleeve (F) fit together.
Use only AEG accessories and spare parts. Should components need to be
replaced which have not been described, please contact one of our AEG service
agents (see our list of guarantee/service addresses).
Please clean the cutting blades after each use. For easy and quick care of the
blades we recommend to spray the blades with cleansing agent. This keeps up the
cutting efficiency.
Cutting time
Storage and
transport
Cleaning
Changing the
blades
Maintenance
Torx TX 20
Torx TX 25
A
F
E
D
C
B