5.4.8 Mode settings
The default mode of series grid-tied solar inverter is “independent”; however, if the current of solar modules are joined
into the inverter as figure 26 shows, it is necessary to switch the mode to “parallel”.
Figure 26: ‘Parallel’ input mode
Only when the DC voltage is high enough, the LCD display is working, and the AC switch
is off, it is possible to modify the inverter DC input mode via the LCD screen and keypad.
5.5 Choice of grid standard
After powering up the inverter by DC input for the first time or after restoring factory settings, a list of countries will
show as in Figure 16L
C o u n t r y : U n s e t
Germany
U K
A u s t r a l i a
G r e e c e
D e n m a r k
H o l l a n d
C o u n t r y : U n s e t
Other
D e n m a r k
H o l l a n d
C h i n a
T h a i l a n d
G r e e c e
Figure 16L: Country list
Press the “ ” or “ ” button to select the country, and press the ENT button to complete the setting.