If the first reading attempt is not successful there are more reading attempts until the TOR time is expired or
one reading attempt was successful (reader received the ID code by the transponder). During the whole read-
ing cycle the exciter stays on. If all reading attempts stay unsuccessful a no read message is sent to the com-
munication partner. If reading was successful the ID code is sent.
Figure 12: Software triggered reading mode with TOR > 0
Attention: During a reading cycle, during the TOR time, there is no no read output in operation mode 2!
This operation mode is factory setting. For further configuration and adaption to the application, use the fol-
lowing commands:
MD 2
Command mode
CID 0
No suppression of equal ID codes
CN 0
No suppression of no read messages
TOR XYZ
Maximal time the exciter is on. Maximal reading time x 0,1s. It takes this time until a no
read message is sent.
TOR 5 – factory setting
NID X
Additional error protection. Internal comparison of the transponder codes.
NID 1 – 2 out of 2 selection
NID 0 – 1 out of 1 selection (no error protection on reader level)