---------------------------------------------------------------13/36-------------------------------------------------------------
The data format used in online mode to transmit the transponder codes is as follows:
Example:
ASCII
STX A
1
1
2
0
0
0
9
6
9
0
0
0
0
0
0
0
0
1
0
2
0 CR LF
Hexadecimal
02
31 31 31 32 30 30 30 39 36 39 30 30 30 30 30 30 30 30 31 30 32 30 0D 0A
The transponder code is transmitted as ASCII string the transmission is completed by the
control characters <CR> <LF>.
The online mode could be terminated by choosing another mode selection within the operation
mode menu.
Once the online mode is active, the ARE H9 will be automatically in the online mode when it
switched on again after switched off.