38
Regulations, Standards, Guidelines
This appliance was designed for household use and was manufactured
in accordance with the appropriate standards.
The necessary measures in accordance with appliance safety legislation
regulations (GSG), accident prevention regulations for refrigeration
appliances (VBG 20) and the regulations of the German Society of
Electrical Engineers (VDE) were observed in the manufacture of this
appliance.
The refrigerant circuit has been checked for leaks.
;
This appliance is in accordance with the following EU guidelines:
– 73/23/EWG dated 19 February 1973 - low voltage guidelines.
– 89/336/EWG dated 3 May 1989
(including guideline change notice 92/31/EWG) - EMV guideline.
Special Accessory
You get special accessories through your AEG product supplier.
• Wire shelves:
Instead of the drawers, wire shelves can be inserted. This is especially
then advantageous, if the appliance is used as a refrigerator or as
drinks cooler.
Technical Terminology
•
Refrigerant
Fluids, which are used for refrigeration are called refrigerants. They
have a relatively low boiling point; so low, that the warmth of foods
in the refrigeration appliance can cause them to boil or vaporise.
•
Refrigerant circuit
Sealed circulation system, in which the refrigerant is found. The
refrigerant circuit consists for the most part of an evaporator, a
compressor, a condenser and tubing.
•
Evaporator
The refrigerant is evaporated in the evaporator. This warmth is
withdrawn from the appliance interior, which is thus cooled. Like all
fluids, refrigerants require warmth in order to be evaporated. For this
reason the evaporator is located in the appliance interior.