Installation
Installation Location
The appliance should be set up in a well ventilated, dry room on a firm and
level surface.
Warning!
The appliance may not be exposed to spray or water splashes.
There is a danger of electrical shock!
Energy use is affected by the ambient temperature.
The appliance should therefore
not be exposed to direct sunlight;
not be installed next to radiators, cookers or other sources of heat;
only be installed at a location whose ambient temperature corresponds
to the climate classification, for which the appliance is designed.
The climate classification is stipulated on the serial plate which can be
found on the inner side of the lid. The following table shows which ambient
temperature is correct for each climate classification:
Climate classification
for an ambient temperature of
SN
+10 to +32 °C
N
+16 to +32 °C
ST
+18 to +38 °C
T
+18 to +43 °C
Model
ARCTIS 189 GT
ARCTIS 261 GT
Volume (gross)
litres
Volume (net)
litres
Height without/with roller
cm
Width
cm
Depth
cm
Weight
kg
Energy consumpt./24h
kWh
Freezing capacity
kg/24h
Hold-over time
hours
Rated power
W
189
184
87,6/88,3
93,5
66,5
49
0,53
23
43
75
261
255
87,6/88,3
119
66,5
57
0,64
27
47
100
Technical Specifications