UsING fUEL sTABILIsER 

Fuel gets old, oxidizes, and breaks down over time. Adding a 

fuel stabiliser extends the usable life of fuel and helps prevent 

deposits from forming that can clog the fuel system. Follow 

fuel  stabiliser  manufacturer’s  directions  for  correct  ratio  of 

stabiliser to fuel.

n

 

Add  stabiliser  to  fuel  tank,  then  fill  with  unleaded  fuel 

following previous instructions.

 

NOTE: 

Fuel stabiliser and unleaded fuel can be mixed 

prior  to  filling  the  tank  by  using  a  gas  can  or  other 

approved fuel container and shaking gently to combine.

n

 

Replace and secure the fuel tank cap.

n

 

Start and run the engine for at least 5 minutes to allow 

stabiliser to treat the entire fuel system.

OXyGENATED fUELs

DO NOT UsE E85 fUEL. IT WILL VOID yOUR 

WARRANTy.
NOTE: 

Some conventional petrol are blended with alcohol or 

an ether compound. This type of petrol is collectively referred 

to as oxygenated fuel; in Australia known as Ethanol. The use 

of ethanol fuel, or fuels containing ethanol is not recommended 

for this product.

  CAUTION:

 

On a level surface with the engine off, check the oil 

level before each use of the generator. 

AC OpERATION

n

 

Unplug all loads from the generator.

n

 

Switch the AC circuit breakers to the OFF (O) position.

n

 

Start  the  engine  (refer  to  "STARTING  THE  ENGINE" 

section. (later on this page)

n

 

Switch the AC circuit breakers to the ON ( I ) position.

n

 

Plug in the appliance.

DC OpERATION

The  DC  terminals  may  ONLY  be  used  for  charging  12  volt 

automotive type batteries.

  CAUTION:

 

The  battery  gives  off  explosive  gases;  keep 

sparks,  flames  and  cigarettes  away.  provide 

adequate  ventilation  when  charging  or  using 

batteries. 

  CAUTION:

 

Battery posts, terminals and related accessories 

contain lead and lead compounds. Wash hands 

after handling.

Connecting the battery cables:

n

 

Before  connecting  the  battery  charging  cables  to 

a  battery  that  is  installed  in  a  vehicle,  disconnect  the 

vehicle ground battery cable from the battery negative (-) 

terminal.

n

 

Connect  the  positive  (+)  battery  cable  to  the  battery 

positive (+) terminal.

n

 

Connect the other end of the positive (+) battery cable to 

the generator positive (+) terminal.

n

 

Connect  the  negative  (-)  battery  cable  to  the  battery 

negative (-) terminal.

n

 

Connect the other end of the negative (-) battery cable to 

the generator negative (-) terminal.

n

 

Start  the  engine.  (refer  to  "STARTING  THE  ENGINE" 

section)

    NOTE: 

Do not start the vehicle while the battery charging 

cable  is  connected  and  the  generator  is  running.  The  

vehicle or the generator may be damaged.

An overloaded DC circuit, excessive current draw by the battery, 

or a wiring problem will trip the DC circuit protector (PUSH 

button extends out). If this happens, wait a few minutes before 

pushing in the circuit protector to resume operation. If the DC 

circuit protector continues to go OFF, discontinue charging and 

see your nearest authorised service centre.

Disonnecting the battery cables:

n

 

Disconnect  the  negative  (-)  battery  cable  from  the 

generator negative (-) terminal.

n

 

Disconnect the other end of the negative (-) battery cable 

from the battery negative (-) terminal.

n

 

Disconnect  the  positive  (+)  battery  cable  from  the 

generator positive (+) terminal.

n

 

Connect the other end of the positive (+) battery cable to 

the battery positive (+) terminal.

n

 

Reconnect the vehicle ground battery cable to the battery 

negative (-) terminal. 

  

sTARTING THE ENGINE 

See Figures 6 - 8.

NOTE:

  If location of generator is not level, the unit may not 

start or may shut down during operation.

n

 

Turn the fuel valve to the ON position.

n

 

Move the choke lever to the START position.

 

NOTE: 

If  engine  is  warm  or  the  temperature  is  above 

10˚C, push the choke lever in to the RUN position.

n

 

Put the engine switch in the ON ( I ) position.

n

 

Pull  the  recoil  starting  grip  until  the  engine  runs  (a 

maximum of 6 times).

 

NOTE:

  Do not allow the grip to snap back after starting; 

return it gently to its original place.

n

 

Allow the engine to run for 30 seconds, then move the 

choke lever in to the RUN position.

Summary of Contents for AGN2400B

Page 1: ...Original Instructions AGN2400B PORTABLE GENERATOR SET ...

Page 2: ...tick air filter choke lever fuel valve Recoil Starter grip FUEL CAP FUEL tank fuel cap oil cap dipstick oil fill hole carburetor drain screw oil cap dipstick Fig 2 Fuel level gauge Fuel level gauge Circuit Breaker oil fill hole fuel tank ...

Page 3: ...Fig 6 ON OFF ON OFF Fig 8 Fig 7 RUN CHOKE CHOKE LEVER TO START choke closed TO run choke open recoil startER grip fuel valve LATCHES air filter cover filter elementS air filter unit Fig 9 ...

Page 4: ...21 2 Fig 10 ON OFF Fig 11 Fig 12 Fig 13 ON OFF ON OFF spark plug cap spark plug fuel line fuel valve BARB fuel valve o ring filter sediment cup oil cap dipstick ...

Page 5: ... are tired or under the influence of drugs alcohol or medication n Keep all parts of your body away from any moving parts and all hot surfaces of the unit n Product users in some states must comply with fire prevention regulations This product is not equipped with a spark arrestor Check with the federal areas or local authorities in your area before use n Do not touch bare wire or receptacles n Do...

Page 6: ...l types of combustible material n Do not operate the generator near hazardous material n Do not operate the generator at a gas or natural gas filling station n Do not touch the muffler or cylinder during or immediately after use they are HOT and will cause burn injury n Do not connect to a building s electrical system unless a transfer switch has been properly installed by a qualified electrician ...

Page 7: ... face shield when operating this product Safety Alert Precautions that involve your safety Electric Shock Failure to use in dry conditions and to observe safe practices can result in electric shock Toxic Fumes Running the generator gives off carbon monoxide an odorless colorless poison gas Breathing carbon monoxide can cause nausea fainting or death Fire Explosion Fuel and its vapors are extremely...

Page 8: ...4 English ...

Page 9: ...5 English ...

Page 10: ...t the engine as described later in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilise engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilise 6 Repeat steps 4 and 5 for each additional load Never add more loads than the generator capacity Ta...

Page 11: ...ype 4 Stroke air cooled OHV Gasoline Bore x Stroke 68x45 Displacement cc 163 Starting System recoil Fuel Type Unleaded fuel Lubrication oil SAE 10W 30 Engine Oil Volume L 0 6 L Fuel Tank Capacity l 15 Max Output hp 5 5 Max Output rpm 3 600 Full Load h 11 Half Load h 20 0 Approvals CE Yes Euro Emission Yes 4m Noise Level LpA dB A 75 4m Noise Level LwA dB A 95 Uncertainty dB A 2 7m Noise Level LpA d...

Page 12: ...ceptacleS Your generator has the following single phase 50 Hz outlets one 230 Volt AC 16 Amp receptacle These can be used for operating appropriate appliances electrical lighting tools and motor loads recoil starter grip The recoil starter grip is used along with the engine switch to start the generator s engine DC TERMINALS The DC terminals may ONLY be used for charging 12 volt automotive type ba...

Page 13: ...ith tools to make you careless Remember that a careless fraction of a second is sufficient to inflict serious injury WARNING Do not use any attachments or accessories not recommended by the manufacturer of this product The use of attachments or accessories not recommended can result in serious personal injury APPLICATIONS This generator is designed to supply electrical power for operating compatib...

Page 14: ...alled in a vehicle disconnect the vehicle ground battery cable from the battery negative terminal n Connect the positive battery cable to the battery positive terminal n Connect the other end of the positive battery cable to the generator positive terminal n Connect the negative battery cable to the battery negative terminal n Connect the other end of the negative battery cable to the generator ne...

Page 15: ...d close latches to secure NOTE Do not run the generator without the air filter Rapid engine wear will result changing engine oil See Figure 10 n Remove the oil cap dipstick n Place a container underneath the oil drainage bolt to collect used oil as it drains n Unscrew the oil drainage bolt and remove n Allow oil to drain completely n Reinstall the oil drainage bolt and tighten securely n Refill wi...

Page 16: ...the barb by squeezing the ends of the retaining clip and sliding the fuel line off n Install one end of a drain line over the barb and place the other end in a fuel container large enough to catch the fuel being drained from the tank n Open fuel valve n When the fuel has drained from the tank close the fuel valve and reinstall fuel line on barb draining the carburetor See Figure 2 n Turn the engin...

Page 17: ...ife Forrecommendations contactyournearestauthorizedservicecenter MAINTENANCE SCHEDULE Before each use After 1st month or 20 hours of operation Every 3 months or 50 hours of operation Every 6 months or 100 hours of operation Every year or after 300 hours of operation Check Engine Oil n Change Engine Oil n n Check Air Filter n Clean Air Filter n Change Air Filter n Clean Carburetor Sediment Cup n Ch...

Page 18: ...cuit breaker is off Item plugged in is defective Turn ON the AC circuit breaker Try a different item Generator makes a spark knock or pinging noise An occasional light knocking or pinging underheavyloadisnotacause for concern However if the knocking or pinging occurs under normal load at a steady engine speed the problem may be with the brand of unleaded fuel being used Switch to a different brand...

Page 19: ...15 English WIRING DIAGRAM AGN2400B ...

Page 20: ...zed reseller or if product is sold AS IS and or WITH ALL FAULTS Where permitted the provisions of this limited warranty are in lieu of any other written warranty whether express or implied written or oral including any warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL WE BE LIABLE FOR SPECIAL INCIDENTAL CONSEQUENTIAL OR INCIDENTAL DAMAGES OUR MAXIMUM LIABILITY SHALL...

Page 21: ...34 0 91 627 93 29 TECHTRONIC INDUSTRIES ASIA CO LTD 24 F CDW Building 388 Castle Peak Road Tsuen Wan Hong Kong Tel 852 2402 6888 RYOBI TECHNOLOGIES GMBH Itterpark 4 D 40724 Hilden DEUTSCHLAND Tel 49 0 2103 2958 0 Fax 49 0 2103 2958 29 RYOBI TECHNOLOGIES GMBH Vertriebsbüro Österreich Schinitzgasse 13 A 8605 Kapfenberg Tel 43 0 3862 23590 0 Fax 43 0 3862 23590 25 TECHTRONIC INDUSTRIES AUSTRALIA PTY ...

Page 22: ......

Reviews: