GB
27
TROUBLESHOOTING
Error/Problem
Possible cause
Correction
red LED lights up
(longer than 3
seconds)
Defective battery
▪
Battery voltage below 15 V
▪
The battery voltage is less than
11 V after 4 minutes
▪
The battery voltage is less than
12 V after 2 minutes
Replace battery
The battery pulser was unable to
fully restore a charge within 86
hours
Replace battery
Terminal connection cable connec-
ted incorrectly
Unplug the battery
pulser and check the
connections
red LED doesn’t
light up
No power supply, battery pulser
not plugged in
Verify the battery
pulser is plugged
into a 230 V power
outlet
Unplug the battery pulser and
check the connections
Unplug the battery
pulser and check the
connections
Defective battery
▪
Battery voltage below 05 V
Replace battery
Low temperatures (below 0 ˚C)
Explosion hazard!
Never charge frozen batteries
Charge battery in
normal conditions