background image

8

8

 

 WARNING

Always wear eye protection with side shields. Failure to do so 
could result in objects being thrown into your eyes, resulting in 
possible serious injury.

 

 WARNING

Do not use any attachments or accessories not recommended 
by the manufacturer of the product. The use of attachments or 
accessories not recommended can result in serious personal 
injury.

 

 WARNING

This equipment incorporates parts, such as snap switches, 
receptacles, and the like that tend to produce arcs or sparks and, 
therefore, when located in a garage, it should be in a room or 
enclosure provided for the purpose, or should be 45 cm or more 

DERYHWKHÀRRU

 

 WARNING

Do not attach any tools to the open end of the hose until start-up 
has been completed.

 

 WARNING

Always remove battery packs from the tool when you are 
assembling parts, making adjustments, cleaning, or when not in 
use. Removing battery packs will prevent accidental starting that 
could cause serious personal injury.

 

 WARNING

Do not use in an environment that is dusty or otherwise 
contaminated. Using the air compressor in this type of 
environment may cause damage to the unit.

APPLICATIONS

Air compressors are utilized in a variety of air system applications. 
Match hoses, connectors, air tools, and accessories to the 
capabilities of the air compressor.
You may use this product for the purposes listed below:

 

Ŷ

Operating light- to medium-duty air-powered tools

 

Ŷ

Operating air accessories such as air nozzles and automotive 
tire inflators

INSTALLING/REMOVING BATTERY PACKS

See Figure 1.

The compressor can run with one or two battery packs.

NOTE:

 For best performance, install two fully-charged battery 

packs before beginning operation. Minimum recommended battery 
capacity is 4.0 Ah per battery pack.

 

Ŷ

Make sure the air compressor is turned off.

 

Ŷ

Insert each battery pack into the product as shown.

 

Ŷ

Make sure the latches on each side of the battery pack snap 
into place and the battery pack is secured in the product before 
beginning operation.

 

Ŷ

Depress the latches to remove the battery pack.

For complete charging instructions, see the operator’s manuals for 
your battery pack and charger.

CONNECTING/DISCONNECTING AIR HOSE (HOSE NOT 
PROVIDED)

See Figure 2.

 

 WARNING

Never exceed the air tool’s pressure rating as recommended by 

WKHPDQXIDFWXUHU:KHQXVLQJWKLVDLUFRPSUHVVRUDVDQLQÀDWLRQ
GHYLFHDOZD\VIROORZWKHPD[LPXPLQÀDWLRQJXLGHOLQHVVWDWHGE\
WKHPDQXIDFWXUHURIWKHLWHPEHLQJLQÀDWHG

 

Ŷ

Make sure the air compressor is turned off and the battery 
packs are not installed.

 

Ŷ

Rotate pressure regulator knob fully in the counter-clockwise 
direction so that the outlet pressure is at zero bar (0 psi).

 

Ŷ

Attach hose with quick connect air fitting to 1/4 in. quick coupler 
on air compressor. Make sure to push the hose adapter end 
fully into the coupler until the sleeve springs forward to lock it 
in place.

To disconnect an air hose or an air tool:

 

Ŷ

Confirm that the outlet pressure is at zero bar (0 psi).

 

Ŷ

When disconnecting a hose from 1/4-in. quick coupler, always 
firmly hold release end of hose.

 

Ŷ

Pull back on the release sleeve on the 1/4-in. quick coupler.

 

Ŷ

With a firm grip, pull out the quick-connect air fitting that is 
attached to the quick coupler.

BREAK-IN PERIOD

%HIRUH¿UVWXVHLQVWDOOWZRIXOO\FKDUJHG$KEDWWHU\SDFNV5XQ

the air compressor at zero tank pressure with the drain valve fully 
open for 30 minutes or until both battery packs are completely 

GLVFKDUJHGZKLFKHYHUKDSSHQV¿UVW

TURNING THE AIR COMPRESSOR ON/OFF

See Figure 3.

 

Ŷ

Install the battery packs.

 

Ŷ

Move the Auto On/Off switch to the AUTO ON (I) position to 
power the compressor on.

 

Ŷ

To turn the air compressor off, move the Auto On/Off switch to 
the OFF (O) position.

NOTE:

 When the compressor is in the AUTO ON (I) position, the 

air compressor will automatically turn back on when the designated 
tank air pressure drops below the preset pressure limit. It will also 
shut off again when the cut-off pressure is reached.

 

 WARNING

Never exceed the air tool’s pressure rating as recommended by 

WKHPDQXIDFWXUHU:KHQXVLQJWKLVDLUFRPSUHVVRUDVDQLQÀDWLRQ
GHYLFHDOZD\VIROORZWKHPD[LPXPLQÀDWLRQJXLGHOLQHVVWDWHGE\
WKHPDQXIDFWXUHURIWKHLWHPEHLQJLQÀDWHG

 

 WARNING

Always ensure the switch is in the OFF (O) position and the 
regulator pressure gauge reads zero before changing air tools or 
disconnecting the hose from the air outlet. Failure to do so could 
result in possible serious personal injury.

USING THE AIR COMPRESSOR

See 

¿

gure 

.

Summary of Contents for 6230329

Page 1: ...BAC218E ...

Page 2: ...2 2 Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modifications ...

Page 3: ...valve 9 Hose wrap strap 10 Air filter assembly 1 Battery packs 2 Depress latches to release battery pack 1 Pressure regulator knob 2 Quick connect coupler 0 75 100 125 150 17 5 20 0 5 1 15 18 50 25 0 75 100 125 150 17 5 20 0 5 1 15 18 50 25 0 75 100 125 150 17 5 20 0 5 1 15 18 50 25 0 75 100 125 150 17 5 20 0 5 1 15 18 50 25 1 1 8 6 2 2 1 2 4 9 10 5 7 3 Fig 1 Fig 2 ...

Page 4: ...then push in to lock 0 75 100 0 5 1 18 50 25 0 75 100 125 150 17 5 20 0 5 1 15 18 50 25 1 Safety valve 2 Pull to release pressure 1 Air filter 2 Air filter cover 3 Air filter housing 0 75 100 125 150 17 5 20 0 5 1 15 18 50 25 0 75 100 125 150 17 5 20 0 5 1 15 18 50 25 0 75 100 125 150 17 5 20 0 5 1 15 18 50 25 1 Drain valve 2 ON open position 3 OFF closed position 1 1 1 4 5 2 2 1 3 3 2 Fig 3 Fig 7...

Page 5: ... children be involved in the work touch the tool or the extension cord and keep them away from the work area Store idle tools When not in use tools should be stored in a dry locked up place out of reach of children Do not force the tool It will do the job better and safer at the rate for which it was intended Use the right tool Do not force small tools to do the job of a heavy duty tool Do not use...

Page 6: ... VSUD LQJ RU VSUD ZKHUH VSDUN RU ÀDPH LV SUHVHQW HHS compressors as far from the spraying area as possible at least 6 m from the spraying area and all explosive vapors Risk of bursting Do not adjust regulator to result in output pressure greater than marked maximum pressure of attachment Do not use at pressure greater than 8 3 bar 120 psi To reduce the risk of electric shock do not expose to rain ...

Page 7: ...WKH SUHVHQFH RI RSHQ ÀDPH Q H SORGHG EDWWHU FDQ SURSHO GHEULV DQG FKHPLFDOV I H SRVHG ÀXVK with water immediately Do not charge battery tool in a damp or wet location Following this rule will reduce the risk of electric shock For best results your battery should be charged in a location where the temperature is more than 10 C but less than 38 C To reduce the risk of serious personal injury do not ...

Page 8: ...rger CONNECTING DISCONNECTING AIR HOSE HOSE NOT PROVIDED See Figure 2 WARNING Never exceed the air tool s pressure rating as recommended by WKH PDQXIDFWXUHU KHQ XVLQJ WKLV DLU FRPSUHVVRU DV DQ LQÀDWLRQ GHYLFH DOZD V IROORZ WKH PD LPXP LQÀDWLRQ JXLGHOLQHV VWDWHG E WKH PDQXIDFWXUHU RI WKH LWHP EHLQJ LQÀDWHG Ŷ Make sure the air compressor is turned off and the battery packs are not installed Ŷ Rotate...

Page 9: ...able container NOTE Condensate is a polluting material and should be disposed of in compliance with local regulations Ŷ If a drain valve is clogged release all air pressure remove and clean valve then reinstall WARNING Turn off the air compressor remove battery packs and release all air from the tank before servicing Failure to depressurise tank before attempting to remove valve could cause seriou...

Page 10: ...doing any maintenance on the machine WARNING For greater safety and reliability all repairs should be performed by an authorised AEG service centre Use only AEG accessories and spare parts Should components need to be replaced which have not been described please contact one of our AEG service agents see our list of guarantee service addresses If needed an exploded view of the product can be order...

Page 11: ...area Turn off unit and allow to cool remove and reinstall battery packs Air tank pressure drops when compressor shuts off RRVH FRQQHFWLRQV WWLQJV WXELQJ HWF Loose drain valve open drain valve Check valve leaking Check all connections with soap and water solution and tighten Tighten drain valve close drain valve Take compressor to service centre DANGER Do not disassemble check valve tank drain valv...

Page 12: ...Techtronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Melbourne Australia Techtronic Industries N Z Limited 2 Landing Drive Mangere Auckland 2022 New Zealand 961096341 01B ...

Reviews: