Installation Instructions
80
UK only
1
Any electrical work required to install this hob should be carried
out by a qualified electrician or competent person, in accordance
with the current regulations.
1
This hob must be earthed.
The manufacturer declines any liability should these safety measures
not be observed.
This hob is designed to be connected to a 230-240 50 HZ AC electrical
supply.
Before switching on, make sure the electricity supply voltage is the
same as that indicated on the hob rating plate. The rating plate is
located on the bottom of the hob.
The hob is supplied without supply cable. A 3 core flexible supply cable
must be fitted, in accordance with the specifications given in the table.
The hob must be connected to a double pole switch with a minimum
gap of 3 mm. Between the switch contacts and of a type suitable for
the required load in compliance with the current electric regulations.
The switch should be sited within 2 m of the hob and be easily accessi-
ble upon completion of the installation.
The switch must not break the yellow and green earth cable at any
point.
Connection via
Min. size Cable/Flex
Cable/Flex Type
Fuse
Cooker Control Cir-
cuit
6 mm
2
PVC / PVC twin and
earth
30 Amp