Safety information

These warnings are provided in the 
interests of your safety. Ensure you 
fully understand them before installing 
or using the appliance. Your safety is of 
paramount importance. If you are 
unsure about the meaning of these 
warnings contact the Customer Care 
Department for assistance.

Installing

Do not install the hob if the ceramic 
glass is damaged or cracked.

This gas hob must be installed 
according to the instructions supplied. 
Any installation work must be 
undertaken by a authorised competent 
person.

Do not alter the specifications or 
attempt to modify the appliance in any
way.

During Use

The gas hob is intended for domestic 
cooking only. It is not designed for 
commercial/industrial purposes.

Ensure that all the control knobs are in 
the OFF position when not in use.

Do not use the gas hob if it is damaged 
in any way, contact your local AEG
Service Centre;
1 Stamford Road
Oakleigh Victoria 3166
Telephone 1300 650020

Never use plastic or aluminium dishes 
on the gas hob.

Never leave the gas hob unattended 
while deep fat frying, or heating fats 
and oils.

Do not use or store flammable 
materials near this appliance. Do not 
spray aerosols in the vicinity of this 
appliance while it is in operation. 
Where this appliance is installed in 
marine craft or caravans, it shall 

not

 be 

used as a space heater

The appliance is not intended for use 
by young children or infirm
persons without supervision.

Child Safety

Young children should be supervised 
to ensure that they do not play
with the appliance

The gas hob gets hot when it is in use. 
Children should be kept away until the 
gas hob has cooled.

Maintenance and Cleaning

Only clean this gas hob in accordance 
with the instructions given in this 
book.

Summary of Contents for 3531 WK-m

Page 1: ...r of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world 3531 WK m INSTRUCTION BOOK ...

Page 2: ...re of the operating instructions enables you to use them as a reference manual The first part of the operating instructions contains a general description of your new product Then follows a short introduction of the things to do before you use the Hob for the first time The section How to use describes how the Hob is used in everyday life Use this section until you are familiar with your new Hob T...

Page 3: ...ion electrode A 8 Thermo Sensor B 8 Ignition 10 Cleaning and maintenance 11 Splashguard 11 Stainless steel surfaces 12 The ceramic glass plate 12 Cleaning of gas burner 12 Service 20 For the installer Mounting 13 Technical data 19 Table of contents 1 2 Step by step Safety information Hint and tips Environmental information How to read the operating instructions 3 ...

Page 4: ... the OFF position when not in use Do not use the gas hob if it is damaged in any way contact your local AEG Service Centre 1 Stamford Road Oakleigh Victoria 3166 Telephone 1300 650020 Never use plastic or aluminium dishes on the gas hob Never leave the gas hob unattended while deep fat frying or heating fats and oils Do not use or store flammable materials near this appliance Do not spray aerosols...

Page 5: ...d persons may cause injury or serious malfunction of the appliance Repairs must only be carried out by a authorised person Contact your local AEG Service Centre 1 Stamford Road Oakleigh Victoria 3166 Telephone 1300 650020 Disposal Make the gas hob unusable by cutting off the cable Dispose of any packaging material and old appliances at an authorised disposal sites The primary air intake aperture M...

Page 6: ...S APPLIANCE MUST BE CONNECTED TO AN EARTHED GENERAL PURPOSE OUTLET Type of gas Adjusted for natural gas 1 0 kPa test point pressure Q Nominal gas consumption NG Wok burner 13 0 MJ h Total 13 0 MJ h AUS NZL Convertible to universal LPG Propane 2 75 kPa test point pressure Q Nominal gas consumption universal LPG Wok burner 13 7 MJ h Total 13 7 MJ h Hob is approved in accordance with AS4551 AG101 Aus...

Page 7: ...rect method of operation If the appliance fails to operate correctly after all checks have been made refer to the authorised service provider in your area The units externally measured length 145 mm Cooker hood 290 mm Two zone ceramic top electric hob Two burner gas hob Grill Fryer Wok 580 mm Four zone ceramic top electric hob Four burner gas hob 725 mm Four zone ceramic top electric hob 7 Burner ...

Page 8: ...ll ensure that a spark is emitted between the ignition electrode and the burner cover Thermo Sensor B The hob unit features fully secured gas taps thermo fuse In case the flame goes out the thermo sensor automatically prevents gas admission after a few seconds max 90 seconds Note Gas admission is always allowed while the operation button is pressed See start up procedure Burner Main nozzle Burner ...

Page 9: ...ppliance inlet with the large and simmer burners operating at maximum Use of Hose Assemblies If the appliance is to be installed using a hose assembly then 1 The hose must be AGA certified to AS NZS 1869 as class B or class D and utilised in accordance with requirements of AS 5601 AG 601 2 The connection point between the consumer piping and the hose must be accessible with the appliance installed...

Page 10: ...as inlet The location of the gas inlet is approximately 240mm form the right hand side of the appliance and 40mm from the back of the appliance The connection of the Gas Regulator is Gas female thread and the pressure at the test point should be adjusted to1 00kPa with the large and simmer burners operating at maximum For Universal LPG connection the appliance needs to be first converted using the...

Page 11: ...h two burner unit For unit combinations a reinforcement beam must be used between each unit It is not necessary to attach the reinforcement beam to the table surface as it is held in place by a specially designed moulding which is incorporated in the hob units flanges Minimum distance to side wall 150 mm Minimum distance to back wall non flammable material 50 mm Reinforcement beams 11 Cleaning and...

Page 12: ...he gas ring is used again so that the boil over does not permanently scar the enamel or paint 13 Mounting This appliance must be installed by an authorised person This appliance shall be installed in accordance with the manufacturer s installation instructions local gas fitting regulations municipal building codes AS5601 AG601 Australian Standard Gas Installations and any other relevant statutory ...

Reviews: