Installation - for contractors
INSTALLATION
7.
Safety
Only qualified contractors should carry out installation,
commissioning, maintenance and repair of the appliance.
7.1
General safety instructions
We guarantee trouble-free functioning and operational
reliability only if the original accessories and spare parts
intended for the appliance are used.
7.2
Instructions, standards and regulations
Observe all applicable national and regional regula
-
tions and instructions.
7.2.1
Important information
– Pressurised connection:
◦
Never exceed the operating pressure of 0.6 MPa.
◦
Route the blow-off line of the safety valve with a fall
and leave open to atmosphere.
◦
The safety valve requires regular maintenance and
activation.
– Unpressurised connection:
◦
Never exceed the operating pressure of 0 MPa.
◦
Do not install a safety valve.
8.
Appliance description
The appliance is designed for undersink installation for
the heating of cold water.
The internal steel cylinder has a special enamel coating
and is equipped with a protective anode. The anode pro-
tects the internal cylinder against corrosion.
– Pressurised connection:
The appliance is designed to supply one or several draw-
off points. It must only be operated with pressure tested
taps. In addition, a type-tested diaphragm safety valve
with non-return valve must be installed.
– Unpressurised connection:
The appliance is designed to supply one draw-off point. It
must only be operated with an open (unpressurised) tap.
8.1
Standard delivery
Delivered with the appliance are:
2
1
3
26
_0
2_0
6_0
19
0
1 Reducer G 1/2 - G 3/8
2 Power cable with plug
3 Diaphragm safety valve with non-return valve for
pressurised connection
4 Fixing materials: 2 screw hooks and 2 rawl plugs
9.
Installation
9.1
Installation information
!
Risk of damage
Carry out all water connection and installation work
in accordance with regulations.
!
Risk of damage
The water heater will no longer function if the water
connections at the appliance are swapped over.
– Pressurised connection:
» Install a pressure reducer upstream of the diaphragm
safety valve in the water line if the static pressure
exceeds 0.48 MPa.
9.2
Installation location
The appliance is exclusively designed for installation on
a solid wall. Ensure the wall offers adequate load bearing
capacity.
Always install the appliance vertically, with the water con-
nections pointing upwards, in a room free from the risk of
frost and near the draw-off point.
– Pressurised connection:
Only install pressure tested taps in conjunction with the
diaphragm safety valve.
26
_0
2_0
6_0
18
8