background image

58

Before you move please contact your nearest Customer Care Centre, listed
below, to give them details of your new home.They will then ensure that the
local Service Organisation is aware of your move and able to look after you
and your appliances.

France

Senlis

+33 (0) 44 62 29 29

Germany

Nürnberg

+49 (0) 911 323 2600

Italy

Pordenone

+39 (0) 1678 47053

Sweden

Stockholm

+46 (0) 8 738 7910

UK

Slough

+44 (0) 1753 219899

Summary of Contents for 1300 D

Page 1: ...spirante Cooker Hood Campana extractora Exaustor Montage und Gebrauchsanweisung Installatie en gebruksaanwijzing Manuel de montage et d utilisation Operating and Installation Instructions Instrucciones de montaje y manejo Manual de Instruções ...

Page 2: ...eration 60 Maintenance and care 61 Metal grease filter Carbon filter Changing the light bulb Cleaning Special accessories Technical assistance service Guarantee conditions Service Technic Details 67 Installation 68 Electrical connection Wall unit mounting Wall mounting Printed on recycled paper AEG putting words into action ...

Page 3: ...the hood including replacing the light bulb take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker It is very important to clean the hood and replace the filter at the recommended intervals Failure to do so could cause grease deposits to build up causing a fire hazard for kitchen unit installer When used as an extractor unit the hood must be fitted with a 120mm ...

Page 4: ...h appliances connected to a chimney if the room and or flat air environment combination is ventilated from outside using a suitable ventilation hole approxi mately 500 600 cm2 large to avoid the possibility of a depression being created during operation of the hood If you have any doubts contact the relevant controlling authority or building inspector s office Since the rule for rooms with fuel bu...

Page 5: ... connect up the hose you should first fit the bayonet mounting flange C Ø 120 mm on the outlet required if using the top outlet fix the flange in place using the screw supplied as shown in Fig 1 Close off the unused hole using the bayonet fitting caps D Fig 1 Warning If is decided to use the rear outlet hole B first remove the sponge E that closes that hole Fig 2 Filter Version The air is filtered...

Page 6: ...thus ensuring all cooking odours are eliminated The control switches are located on the unit s front panel Light switch this switch is used to turn the light fitted in the hood on and off Extractor fan switch used to turn the fan off Push button 1 used to set the fan to speed 1 Push button 2 used to set the fan to speed 2 Push button 3 used to set the fan to speed 3 Light switch Extractor fan swit...

Page 7: ...back and then extract the filter by pulling downward Fig 4 Dishwasher machine Place grease filters in dish washer Select most powerful washing programme and highest temperature at least 65 C Repeat the process Refit the grease filters when it are dry When washing the metal grease filter in the dishwasher a slight discoloration of the filter can occur this does not have any impact on its performanc...

Page 8: ...s gets stuck on the filter and later causes bad odours To reactivate the carbon the filter should be dried in an oven for 10 minutes with a temperature of maximum 100º C After approximately three years of use the carbon filter should be replaced with a new as the odour reduction capacity will be reduced Mounting Remove the grease filters and fit one LONG LIFE carbon filter S on the rear side of ea...

Page 9: ...or s protective grid Wash the outside surfaces using a delicate detergent solution Never use caustic detergents or abrasive brushes or powders Only ever clean the switch panel and filter grille using a damp cloth and delicate detergents It is extremely important to clean the unit and change the filters at the recommended intervals Failure to do so will cause grease deposits to build up that could ...

Page 10: ...sed agent AEG reserves the right to stipulate the place of the repair i e the customer s home place of installation or AEG workshop 4 The guarantee or free replacement includes both labour and materials 5 Repairs carried out under guarantee do not extend the guarantee period for the appliance Parts removed during guarantee repairs become the property of AEG 6 The purchaser s statutory rights are n...

Page 11: ... of your new home They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances France Senlis 33 0 44 62 29 29 Germany Nürnberg 49 0 911 323 2600 Italy Pordenone 39 0 1678 47053 Sweden Stockholm 46 0 8 738 7910 UK Slough 44 0 1753 219899 ...

Page 12: ... a plug can be connected to any standard power socket within easy access Should it be necessary to provide a fixed connection the hood must only be installed by an electrician authorised by the local electricity board When installing an omnipolar disconnector with a distance of at least 3 mm between contacts must be provided The manufacture declines all responsibility for malfunctions resulting fr...

Page 13: ... cupboard 2 using the drilling template 1 Provide an hole also for exhausting pipe 4 ONLY if is decided to use the hood in Exhausting version 3 From inside the cupboard insert the 4 supplied screws 5 and tighten them in the appropriate holes on the appliance Fig 6 ...

Page 14: ...er points Insert the three Ø 8mm expansion plugs into the wall 4 Insert 2 5x45 screws 5 but do not tighten them completely hang the hood 6 Adjust the unit so that it is positioned at a right angle to the wall by turning the two screws on lower side 7 Tighten the 2 upper screws 8 From inside the hood insert the third 5x45 screw into the lower hole 9 and tighten 10 2 3 4 4 4 5 5 3 1 6 6 9 8 1cm 5 10...

Reviews: