background image

3

OVERVIEW

ON / MEASURE

 

On

 

Measure

 

Continuous Measurement (push 2 sec)  

+ Min / Max Function

ADD

 

Add value

 

Navigate in memory menu

AREAS / VOLUMES

 

Area (push 1x)

 

Volume (push 2x)

 

Indirect Surface Measurement (push 3x / 4x))

POWER

 

On

 

Off (push 2 sec)

 

Clear

SUBTRACT

 

Subtract value

 

Navigate in memory menu

PYTHAGORAS

 

Pythagoras 1 (push 1x)

 

Pythagoras 2 (push 2x)

 

Pythagoras 3 (push 3x)

CHANGE POINT OF MEASURE

 

Front 

 

► Back (Standard automatical)

 

Corner pin

MEMORY

 

Timer 3-15 sec (push 1x)

 

Memory 1-20 (push 1x, 2 sec)

 

Use +/- to navigate the measures in memory

Single Pythagoras 

Height difference

Minimum / Maximum for continuous Measure

Area/ Volume 

Indirect Surface Measurement

Battery Status

Memory

Timer

Continuous measure mode

Addition / Subtraction

Main Value

Among Values

Measuring Reference

Normal Measuring Mode

Summary of Contents for AEGLDM50

Page 1: ......

Page 2: ...st liquids and high humidity These may damage internal components or affect accuracy Do not use aggressive cleaning agents or solutions Use only a clean soft cloth for cleaning Avoid heavy impact to o...

Page 3: ...ted for normal use TECHNICAL DATA Dust and Water resistance IP54 Receiving Lens 14 mm Focus 35 mm Maximum Measuring Range 50 meters Minimum Measuring Range 0 05 meters Absolute Accuracy 10m 1 5 mm Max...

Page 4: ...AGORAS Pythagoras 1 push 1x Pythagoras 2 push 2x Pythagoras 3 push 3x CHANGE POINT OF MEASURE Front Back Standard automatical Corner pin MEMORY Timer 3 15 sec push 1x Memory 1 20 push 1x 2 sec Use to...

Page 5: ...4 1 2 3 1 3 2 2x AAA click CHANGE BATTERIES CORNER PIN Change batteries when battery symbol is flashing BELT CLIP...

Page 6: ...5 90 90 90 FUNCTION SWITCH PYTHAGORAS MEASURING REFERENCE Area Starting Point of Measure Pythagoras 1 Front Back Standard automatical Corner Pin Pythagoras 2 Pythagoras 3 Volume Wall Distance...

Page 7: ...6 0 1 2 3 4 5 1 3 5 SINGLE DISTANCE MEASURING...

Page 8: ...7 0 1 2 3 4 2 sec Stop MIN MAX MIN MAX MAX 2 sec 90 2 PERMANENT MINIMUM MAXIMUM MEASURING...

Page 9: ...8 0 1 2 3 1 3 1 000 m ADD SUBTRACT MEASURING...

Page 10: ...9 1 2 1 x 0 1 2 AREA MEASURING...

Page 11: ...10 1 3 2 2 x 0 1 2 3 VOLUME MEASURING...

Page 12: ...11 0 1 2 2 1 90 1 x INDIRECT MEASURING PYTHAGORAS 1...

Page 13: ...12 0 1 2 3 2 x 90 1 3 2 INDIRECT MEASURING PYTHAGORAS 2...

Page 14: ...13 1 2 3 4 1 2 3 90 3 x INDIRECT MEASURING PYTHAGORAS 3...

Page 15: ...14 0 1 2 3 3 x 4 5 1 2 3 4 5 WALL AREA MEASURING SCENARIO 1...

Page 16: ...15 0 1 2 3 4 x 4 5 3 4 5 1 2 WALL AREA MEASURING SCENARIO 2...

Page 17: ...ing the button Push button The seconds are counted down until the measurement starts At 0 the measurement starts The measured values are stored continuously and automatically in memory The stored valu...

Page 18: ...device and push button Lasericon flashes flashing green illustrated Icon is displayed Icon appears Measured parameter flashes flashing green illustrated Measured value appears briefly in the main lin...

Page 19: ...sh 7 Exit memory Push button 8 Switch off Push button 2 sec Memory must be exited before Stored values appears in the main line Associated icon appears and measured parameter flashes flashing green il...

Reviews: