![AEG Electrolux DI9611-M Installation And Operating Instructions Manual Download Page 13](http://html1.mh-extra.com/html/aeg-electrolux/di9611-m/di9611-m_installation-and-operating-instructions-manual_2860236013.webp)
EN
2
24
ELECTRICAL CONNECTION
• Connect the Hood to the mains power supply, inserting a two-
pole cut-out switch with contact aperture of at least 3 mm
along the line.
• Pull the Comfort Panel to open it, ensure that the supply cable
connector is properly inserted into the Suction device socket
• Join the connectors.
• Install the odour filter and the charcoal filter in case the hood is
to be used in recycling version.
• Install the grease filter again, and successively the suction
panel.
Lux
Cmd
Flue assembly - Mounting the hood body
• Position the upper chimney section and fix the upper part to the
frame using the 2 screws
12c
(2,9 x 6,5) provided.
• Similarly, position the lower chimney section and fix the
lower part to the frame using the 2 screws
12c
(2,9 x 6,5) pro-
vided.
Before fixing the hood body to the frame:
• Remove the grease filters from the hood body.
• Remove any activated charcoal filters.
• From below, use the 4 screws
12f
(M6 x 10)provided to fix the
hood body to the frame.
12f
12c
12c
Glass Assembly
• Unscrew
Vx
to fix the glass.
• Please set the glass
26
on the Body Hood being careful that
both supports are correctly positioned.
• Fix the glass with the two screws
Vx
previously removed.
26
Vx
Vx
26