Installation Instructions
Installation
• The set-up of the electrical installation is arranged so that the appliance can be isolated
from the mains with a minimum 3 mm all-pole contact separation.
Suitable isolation devices include, for example, circuit breakers, fuses (screw type fuses
are to be removed from the holder), RCDs and contactors.
• Anti-shock protection must be provided by the installation.
• The built-in unit must meet the stability requirements of DIN 68930.
• Built-in cookers and cooking surfaces are equipped with special attachment systems. For
safety reasons, they must only be combined with appliances from the same manufac
-
turer.
The use of heat protection strips is prohibited for cookers and ovens with Pyrolytic Cleaning,
if the recess has a rear wall and closed ground-level compartment.
However installation is possible with a ground-level compartment that has been shortened
by at least 20 mm and which has base ventilation of the same cross-section.
550 min
600 min
888
866
300 min
560 min
570 max
2000 min
907 min
538
20
42
Installation