MOUNTING AND MAINTENANCE 

INSTRUCTION

Luminaire closure 

To close the luminaire, follow the directive from Pic. 10 to Pic. 12. 

Fig. 10

 

Fig. 11

 

Fig. 12

 

Lift the upper frame 

Unlock the hinge and move down the 

upper frame 

Initial position 

LED module extraction 

1) Disconnect the LED

connector (C);

2) Loosen the screws (E);
3) Extract the LED

modules.

LED module repositioning 

1) Replace in the original

position the LED 
modules; 

2) Tighten the screws (E);
3) Connect the LED

connector (C).

Gear tray extraction 

1) Disconnect the mains

connector (B);

2) Disconnect the LED

connector (C);

3) Loosen the screws (D);
4) Extract the gear tray.

Gear tray repositioning 

1) Replace in the original

position the gear tray; 

2) Tighten the 2 screws (D);
3) Connect the LED connector

(C);

4) Connect the mains 

connector (B).

SPD MAINTENANCE

 

The protection device is equipped with system that excludes power supply at the end of life of the luminaire. 
If the luminaires switches-off when the system is still fed, the activity of the protection device should be checked looking at signaling 
LED. 
To check this, use the appropriate tool

. For more details contact the manufacturer.

 

LED ON _ Right functioning of the SPD 

LED OFF _ End of life SPD, replace the SPD 