ITALO 2_IM_ENG - Rev.03 of 27/10/14
Page 3 of 4
MOUNTING AND MAINTENANCE
INSTRUCTION
Luminaire closure
To close the luminaire, follow the directive from Pic. 10 to Pic. 12.
Fig. 10
Fig. 11
Fig. 12
Lift the upper frame
Unlock the hinge and move down the
upper frame
Initial position
LED module extraction
1) Disconnect the LED
connector (C);
2) Loosen the screws (E);
3) Extract the LED
modules.
LED module repositioning
1) Replace in the original
position the LED
modules;
2) Tighten the screws (E);
3) Connect the LED
connector (C).
Gear tray extraction
1) Disconnect the mains
connector (B);
2) Disconnect the LED
connector (C);
3) Loosen the screws (D);
4) Extract the gear tray.
Gear tray repositioning
1) Replace in the original
position the gear tray;
2) Tighten the 2 screws (D);
3) Connect the LED connector
(C);
4) Connect the mains
connector (B).
B
D
C
E
D
SPD MAINTENANCE
The protection device is equipped with system that excludes power supply at the end of life of the luminaire.
If the luminaires switches-off when the system is still fed, the activity of the protection device should be checked looking at signaling
LED.
To check this, use the appropriate tool
. For more details contact the manufacturer.
LED ON _ Right functioning of the SPD
LED OFF _ End of life SPD, replace the SPD