8101 OPERATOR’S MANUAL
97-8101002_9-13-12
Information subject to change
21
Dual Channel Mode – Output per Channel, Both Channels Driven
PEAK OUTPUT
RMS OUTPUT
40mSec Pulse,
20% Duty Cycle
5 Minute,
100% Duty Cycle
1 Hour,
100% Duty Cycle
5 Minute,
100% Duty Cycle
1 Hour,
100% Duty Cycle
Ohms
Volts
Amps
Volts
Amps
Volts
Amps
Volts
Amps
Volts
Amps
Watts
open
167
167
167
118
118
16.5
142
8.6
143
8.6
138
8
101
6.1
97.5
5.9
575
8
127
16
101
12.6
98
13
71.5
8.9
69.5
8.7
605
4
103
26
71
18
67
17
50
12.5
47.5
11.9
565
2
71
35
49
25
46
23
35
17.5
32.5
16.3
530
1
43
43
30
30
Not recommended
21.5
21.5
Not recommended
Bridge-Mono Mode
PEAK OUTPUT
RMS OUTPUT
40mSec Pulse,
20% Duty Cycle
5 Minute,
100% Duty Cycle
1 Hour,
100% Duty Cycle
5 Minute,
100% Duty Cycle
1 Hour,
100% Duty Cycle
Ohms
Volts
Amps
Volts
Amps
Volts
Amps
Volts
Amps
Volts
Amps
Watts
open
335
335
335
235
235
16
255
16
202
13
197
12
144
8.9
139
8.7
1209
8
206
26
141
18
134
17
100
12.5
95
11.9
1130
4
141
35
99
25
92
23
70
17.5
65
16.3
1059
2
86
44
59
30
Not recommended
42
21.0
Not recommended
7.2
Output Power