8101 OPERATOR’S MANUAL
97-8101002_9-13-12
Information subject to change
15
Figure 4.2 – Attenuation vs. Detent of Level Controls
●
1.4 V (Gain of 63.9)
●
26 dB gain (Gain of 20)
●
1.4 V (not normally
used).
The Specifications chapter lists
the input sensitivity for the 26 dB
gain setting.
4.2.4
Nominal Attenuation
Settings
The signal level for each input
can be attenuated accurately by
adjusting the 21-step Level
Control (see Section 3.3).
Figure
4.2
shows the attenuation in dB for
each detent. The setting of the
input-sensitivity switch varies the
actual attenuation as shown. The
accuracy of the attenuation varies
with the setting: see Tolerance (dB).
Figure 4.1 – Input Sensitivity Switches Location