97-8004167 07-14-17
Information subject to change
21
7224 & 7226 OPERATOR’S MANUAL –
SECTION 5
5.3.4 Selecting the Best Voltage Poten-
tial and Bi-Level Power Switch Settings
for Your Application
The output of the amplifier will be determined by
the combination of settings used for both Voltage
Potential and Bi-Level Power Switch.
OUTPUT VOLTAGE
BI-LEVEL
SWITCH
SETTING
VOLTAGE POTENTIAL SETTING
High Current
(90V)
High Voltage
(180V)
AUTO
45 - 90
90 - 180
HIGH
90
180
LOW
45
90
Use the following general guidelines to select the
best combination of settings to fit your requirements:
OUTPUT
LOAD
Settings
Continuous
Pulse
High
Voltage
16, 8 ohm
16, 8, 4 ohm
180 V Auto
Mid-
Level
4, 2 ohm
2, 1 ohm
90 V Auto
High
Current
1, 0.5 ohm
0.75 - 0.25
ohm
90 V Low
Also see the
“Specifications”
section for more
information.