AE Conversion PLC Gateway Installation Manual Download Page 10

10

Gateway

11.2013

6.5 Install and Start Software

When the system is energized, please install the 

software on your personal computer or laptop to ensure 

proper operation of the system. 

Insert the included CD-ROM in your CD / DVD drive. It 

will automatically open the installation program, which 

will guide you through the installation.

For direction on how to properly install and use the 

software, please refer to the Software User Manual.

7.0 Troubleshooting

If for any reason the Gateway is not working properly, 

check if the following points:

• 

Is the LED still lit? If the LED is not illuminated, then 

the power supply to the gateway could be a source 

of the problem

• 

Are all connections preformed properly? Are 

connections A and B done correctly?

Adhere to all the safety measures described throughout 

this manual. Qualified personnel can use the following 

troubleshooting steps if the PV system does not operate 

correctly. 

WARNING! 

Do not attempt to repair the AEconversion PLC Gateway 

or the AEconversion Micro-Inverter; it contains no user-

serviceable parts. If it fails, please contact APtonics’ 

Service Department to assist.

WARNING! 

Be aware that only qualified personnel should 

troubleshoot the PV array, AEconversion Micro-Inverter 

or the AEconversion PLC Gateway. 

WARNING!

 

Never disconnect the DC wire connectors under load. 

Ensure that no current is flowing in the DC wires prior 

to disconnecting. An opaque covering may be used to 

cover the module prior to disconnecting the module. 

WARNING!

 

Always disconnect AC power before disconnecting the 

PV module wires from the AEconversion Micro-Inverter. 

The AC connector of the first Micro-Inverter in a branch 

circuit is suitable as a disconnecting means once the 

AC branch circuit breaker in the load center has been 

opened.

WARNING!

 

Open all ungrounded conductors of the circuit to which 

it is connected.

7.1 Troubleshooting a Communication-System

WARNING! 

Be aware that only qualified personnel should 

troubleshoot the PV array, AEconversion Micro-Inverter 

or the AEconversion PLC Gateway. 

To troubleshoot an inoperable Communication-System, 

follow the steps in the order shown: 

1. 

Verify the connection to the utility grid. Make sure 

that the utility frequency and voltage are within 

allowable ranges listed in the Technical Data section  

in the appendix of this manual.  

2. 

Make sure that the utility power is present at the 

inverter in question by first removing AC and 

then DC power. Do NOT under any circumstances 

disconnect the DC wires while the Micro-Inverter is 

producing power. 

3. 

Check the AC distribution blocks between all 

the Micro-Inverters. Check that each inverter is 

energized by the electricity network as described in 

the previous step. 

4. 

Any AC disconnects need to be checked if they are 

operating correctly and closed. 

5. 

Check to see if the PV module DC voltage is within 

the allowable range shown in the Technical Data in 

the appendix of this manual. 

6. 

Verify that the DC connections between the Micro-

Inverter and the PV module are connected properly. 

7. 

If the problem persists, please call customer support 

at AEconversion.

7.2 Other Faults

Other faults are reported to the AE-Solar Software. Refer 

to the AE-Solar Installation and Operation Manual for 

troubleshooting procedures. 

8.0 Further Information

The following sections provide further guidance to the 

inverter.

8.1 Disposal

Dispose of the packaging in accordance with generally 

applicable laws and regulations. Keep the environmental 

requirements for recovery, reuse and disposal of 

materials and components.

8.2 Care

The Gateway should generally be kept free of dust and 

dirt.

Summary of Contents for PLC Gateway

Page 1: ...Micro Inverter English Installation Manual PLC Gateway ...

Page 2: ...ATION Product information is subject to change without notice All trademarks are recognized as the property of their respective owners Copyright 2012 AEConversion GmbH Co KG All rights reserved IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS THIS MANUAL CONTAINS IMPORTANT INSTRUCTIONS FOR THE AECONVERSION PLC GATEWAY THAT SHALL BE FOLLOWED DURING INSTALLATION AND MAINTENANCE OF THE GATEWAY ...

Page 3: ...y 7 4 3 LED Light 7 4 4 Protection Concepts 7 5 0 Gateway Pre Installation 7 5 1 Parts and Tools Required 7 5 2 Lighting Surge Protection 8 6 0 Installation Procedure 8 6 1 Measure AC at the Electrical Utility Connection 8 6 2 Mount the Gateway 8 6 3 Connect to Inverters and Grid 8 6 4 Connect RS485 Bus 9 6 5 Install and Start Software 10 7 0 Troubleshooting 10 7 1 Troubleshooting aCommunication S...

Page 4: ...onal Electrical Code NEC ANSI NFPA 70 Be aware that only qualified personnel should install or replace AEconversion PLC Gateway Do not attempt to repair the AEconversion PLC Gateway it contains no user serviceable parts Tampering with or opening the AEconversion PLC Gateway will void the warranty WARNING Do NOT disconnect the Gateway from the installation without first removing AC power For damage...

Page 5: ...ly To reduce the risk of electric shock do not perform any servicing other than that specified in the operating instructions unless you are qualified to do so 2 0 Storage and Transportation For storage and transport the following warnings are to be noted All contacts should be kept dry and clean Transport the Gateway only in the given packaging 2 1 Assembly Installation Operation and Maintenance T...

Page 6: ...onditions radiation were present at the time of the error 2 Information about the PV installation How many Powerline Micro Inverters are installed in the system What AC nominal voltage is used 3 4 Scope of Delivery The package includes Gateway Two wall mounting tabs and screws Quick Start Guide and further information on CD 4 0 Product Description The AEconversion PLC Gateway provides the connecti...

Page 7: ...0 6 1 DIN EN 61000 6 2 DIN EN 61000 6 3 DIN EN 61000 6 4 DIN EN 61000 3 2 DIN EN 61000 3 3 Concerning interference resistance transient emissions circuit feedback for device types 16A 2006 95 EC Directive on electrical equipment designed for use within certain voltage limits according to IEC55011B EMC IEC 60950 UL60950 Safety EIA 485 RS485 Standard Connection of the data cable to Superior Systems ...

Page 8: ...on the AC cabling to be sure that the cable matches the electrical utility service at the site Use 208 VAC 208 VAC three phase cabling at sites with three phase 208 VAC service or use 240 VAC cabling at sites with 240 VAC single phase service Use 240 VAC cable at sites with 208 single phase service Please refer to page 12 208V and 13 240V for wiring diagrams NOTE The operation at grids with neutra...

Page 9: ...he A and B of one gateway to the A and B of the next and so on The last gateway is then connected respectively from A and B of the gateway to A and B of the bus master here USB RS485 Interface Adapter The restrictions to the maximum number of allowable units in one circuit branch are as follows 60 Hz US 60Hz 240V Installations 20A Circuit Breaker US 60Hz 208V Installations 20A Circuit Breaker Type...

Page 10: ...ns once the AC branch circuit breaker in the load center has been opened WARNING Open all ungrounded conductors of the circuit to which it is connected 7 1 Troubleshooting a Communication System WARNING Be aware that only qualified personnel should troubleshoot the PV array AEconversion Micro Inverter or the AEconversion PLC Gateway To troubleshoot an inoperable Communication System follow the ste...

Page 11: ...ation of stability the thermal protection and the aging behavior is required for retrospective installation To comply with the regulations on accident prevention the use of safety systems safety belt scaffolding arresting gear etc may be required These security systems are not included and must be ordered separately The installation must be performed by professionally qualified and authorized pers...

Page 12: ...es a reliable filter to shield communication from external interferences The system data is provided at the RS485 port In order to connect all inverters with a central monitoring station eg the AEconversion Data Logger the gateways can be connected in parallel to the RS485 bus Interfaces RS485 PLC Additional Information Safety standards safety class II Product safety IEC 60950 EMC FFC Part 15 Clas...

Page 13: ...13 11 2013 Gateway Wiring Diagrams 208V NOTE The operation at grids with neutrals which are not grounded is not allowed NOT APPROVED ...

Page 14: ...14 Gateway 11 2013 Wiring Diagrams 240V NOTE The operation at grids with neutrals which are not grounded is not allowed NOT APPROVED ...

Page 15: ...15 11 2013 Gateway AEConversion GmbH Co KG Geseker Str 3 59494 Soest Germany Phone 49 0 521 329471 0 Fax 49 0 521 329471 29 www aeconversion com ...

Reviews: