VP-8-V2 and VP-16-V2 Series Encoder
·
User Manual
36
function.
After the HTTPS feature is enabled, the system will use the HTTPS
login mode by default when you input the IP
address (e.g.,
https://192.0.0.64). You can also input http://IP address/index.asp (e.g.,
http://192.0.0.64/index.asp)
if you want to use HTTP mode to log into the device.
4.3.9
Configuring Multicast Address
Purpose:
The multicast address can be configured to realize live view for more than the maximum number of cameras
through network.
A multicast address spans the Class-D IP range of 224.0.0.0 to 239.255.255.255. It is recommended to use the IP
address ranging from 239.252.0.0 to 239.255.255.255.
Steps:
1.
Click
Remote Configuration > Network Settings > Advanced
to enter the multicast address settings interface.
Figure 4. 23
Multicast Address Settings
2.
Enter the multicast address in the text filed.
3.
Click
Save
to save the settings.
The device will reboot automatically to activate the multicast address settings.
4.3.10
Configuring Remote Alarm Host
Purpose:
With a remote alarm host configured, the device will send the alarm event or exception message to the host
when an alarm is triggered. The remote alarm host must have the CMS (Client Management System) software
installed.
Steps:
1.
Click
Remote Configuration > Network Settings > Advanced
to enter the alarm host settings interface.