A-200 Installation Manual
11
1.3.6
Terminal Resistor Settings
Open the bubble of the dome and you will find the 120
Ω
terminal resistor on the side of the dome
as shown below.
Figure 1-11
Termination Resistor
In half-duplex mode, you can switch the position 2 to ON to enable the resistor;
In full-duplex mode, switch position 2 to ON to enable the resistor of the receiving end, and
switch position 1 to ON to enable the resistor of the sending end.
Note:
The factory default setting for the speed dome is half-duplex.
1.4
Alarm In/Out Connections
The network speed dome can be connected with alarm inputs (0~5VDC) and alarm outputs. Refer to
the following diagrams for alarm output:
JQC-3FG
Relay
30VDC
GND
OUT
L
N
~220V AC
Relay Output
Dome
(10 A 250VAC)
Diagram (left)
Diagram(right)
1A
OUT(n)
OUT(n)
+
-
DC
DC Load
Relay Output
Dome
OUT(n)
OUT(n)
Figure 1-12
Alarm Out Connections
The alarm provides the relay output (no voltage), and the external power supply is required when it
connects to the alarm device.
For DC power supply (left diagram), the input voltage must be no more than 30VDC, 1A.
For AC power supply, the external relay must be used (right diagram) to prevent damages to the
speed dome and avoid risk of electric shock.
ON
2
1
ON
2
1
Summary of Contents for A-200
Page 1: ...A 200 Installation Manual 1 A 200 Speed Dome Installation Manual V1 0 2 ...
Page 20: ...A 200 Installation Manual 14 Figure 2 3 Pole Mount ...
Page 21: ...A 200 Installation Manual 15 2 4 A 200 LPM Figure 2 4 Long Pendant Mount ...
Page 39: ...A 200 Installation Manual 33 Figure A 6 Long arm Wall Mount ...
Page 46: ......