3.3.4

Adhesive Mounting Pad

Fasten WISE-2410 and stud, use adhesive epoxy glue(24hours) to stick on the motor
surface. 
 

Figure 3.8 Adhesive Mounting Pad

3.4

Battery Replacement

1.

Slowly remove top chassis 

 

Figure 3.9 Battery Replacement Step1

2.

Unplug and remove battery pack and its connector

 

Figure 3.10 Battery Replacement Step 2

Summary of Contents for WISE-2410

Page 1: ...User Manual WISE 2410 LoRaWAN Smart Condition Monitoring Sensor ...

Page 2: ...sumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most customers never need to use our repair service If an Advantech product is defective it will be repaired or replaced free of charge during the warranty period For out of warranty repairs customers are billed according to the cost of repl...

Page 3: ......

Page 4: ...odule 1 x Mounting stud 1 4 28 UNF x 9 4Lmm 1 x Quick start manual 2 pcs AA 3 6VDC batteries should be ordered respectively Built in Antenna Warning Warnings indicate conditions that if not observed may cause personal injury Caution Cautions are included to help prevent hardware damage or data losses For example Batteries are at risk of exploding if incorrectly installed Do not attempt to recharge...

Page 5: ... moisture The equipment is malfunctioning or does not operate according to the user manual The equipment has been dropped and damaged The equipment shows obvious signs of breakage 11 Do not leave the equipment in an environment with a storage temperature of below 20 C 4 F or above 85 C 185 F USB powered 50 C 122 F 12 Battery powered as this may cause damage The equipment should be kept in a contro...

Page 6: ...更頻率 加大功率或變更原設計之特性及功能 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經發現有干擾 現象時 應立即停用 並改善至無干擾時方得繼續使用 前項合法通信 指依電信法 規定作業之無線電通信 低功率射頻電機須忍受合法通信或工業 科學及醫療用電波 輻射性電機設備之干擾 VCCI この装置は クラス B 機器です この装置は 住宅環境で使用することを目的とし ていますが この装置がラジオやテレビジョン受信機に近接して使用されると 受 信障害を引き起こすことがあります 使用説明書に従って正しい取り扱いをして下さい VCCI B ...

Page 7: ... Mounting 11 3 3 1 Installation Direction 11 Figure 3 3 WISE 2410 Installation Direction on motor 11 Figure 3 4 WISE 2410 Detail Installation Direction on motor 11 3 3 2 Stud mount 12 Figure 3 5 Stud mount 12 Figure 3 6 Stud mount 12 3 3 3 Magnetic bases 12 Figure 3 7 Magnetic bases 12 3 3 4 Adhesive Mounting Pad 13 Figure 3 8 Adhesive Mounting Pad 13 3 4 Battery Replacement 13 Figure 3 9 Battery ...

Page 8: ...gger 32 4 2 5 Diagnostician 34 4 3 Get Raw Data from WISE 2410 34 4 3 1 Standard operation mode 35 4 3 2 Real Time operation mode 36 Appendix A WISE LPWAN Payload Format 37 A 1 LoRaWAN Frame Payload 38 A 1 1 WHDR Header 38 A 1 2 WPayload 39 A 1 3 WCRC 39 A 1 4 Sensor data I O Type 0x5 39 A 1 5 Device data I O Type 0x6 42 A 2 Packet Fragmentation and Reassembly 43 Appendix B Modbus address 45 ...

Page 9: ...Chapter 1 1 Product Overview ...

Page 10: ... for evaluation of vibration severity Built in antenna support LoRaWAN Powered by battery or USB port IP66 enclosure 1 3 System Architecture WISE 2410 transmits sensor data to WISE 6610 via LoRaWAN or 3rd party LoRaWAN gateway via LoRaWAN WISE 6610 provides Ethernet connectivity and supports Modbus TCP RESTful Web API for integration Figure 1 1 System Architecture Function Model Description LoRaWA...

Page 11: ...Product Overview 1 4 Mechanical Design and Dimensions Figure 1 2 WISE 2410 Dimension 1 5 LED Figure 1 3 LED LED Color Indication Behavior Status Green ON Turn on 2 sec when power on Turn on 1 ms when RF transmission completely OFF Idle ...

Page 12: ...WISE 2410 User Manual 4 ...

Page 13: ...Chapter 2 2 Product Specification ...

Page 14: ...tion temperature Powered by batteries 20 50 C Powered by Micro B USB cable 20 85 C Storage temperature 30 85 C without battery Operating humidity 10 95 RH non condensing Storage humidity 5 95 RH non condensing Note The transmitting distance is subject to the environment of application site Please perform site survey to determine the set up range of the wireless network Note Equipment will operate ...

Page 15: ...e VCP Drivers https www silabs com products development tools software usb to uart bridge vcp drivers 2 6 Sensor Specifications Vibration Sensor Axis X Y Z Frequency Range 10 1000Hz Amplitude Range 16g Detection type Velocity RMS Acceleration RMS peak Advanced Kurtosis Crest factor Skewness Standard deviation Resolution 10 bit Sensitivity 31 2mg LSB TYP Noise 150mg MAX TA 25 C 0g Temperature Senso...

Page 16: ...WISE 2410 User Manual 8 ...

Page 17: ...Chapter 3 3 Mechanical and Hardware Installation ...

Page 18: ...ser Manual 10 3 1 Interface Introduction Figure 3 1 WISE 2410 Interface Introduction 3 2 Tighten two chassis Turn clockwise the top chassis to locking point to tighten bottom chassis Figure 3 2 Tighten two chassis ...

Page 19: ...y described in the following sections 3 3 1 Installation Direction WISE 2410 Builds in 3 axis vibration sensor Please follow the following installation guide to make sure the eigenvalues from your device are correct Figure 3 3 WISE 2410 Installation Direction on motor Figure 3 4 WISE 2410 Detail Installation Direction on motor ...

Page 20: ...mount Fasten WISE 2410 with stud and hold of motor surface Figure 3 6 Stud mount 3 3 3 Magnetic bases Fasten WISE 2410 and stud and then fasten WISE 2410 with stud and magnetic bases Figure 3 7 Magnetic bases Note Please Wrench need to hold base steel not contact chassis when you use Wrench to fasten WISE 2410 with stud to hold of motor ...

Page 21: ... Fasten WISE 2410 and stud use adhesive epoxy glue 24hours to stick on the motor surface Figure 3 8 Adhesive Mounting Pad 3 4 Battery Replacement 1 Slowly remove top chassis Figure 3 9 Battery Replacement Step1 2 Unplug and remove battery pack and its connector Figure 3 10 Battery Replacement Step 2 ...

Page 22: ...nual 14 3 Plug in new battery and make sure the anode and cathod Figure 3 11 Battery Replacement Step 3 Figure 3 12 Battery Replacement Step3 4 Plug in the connector of battery pack Figure 3 13 Battery Replacement Step4 ...

Page 23: ...the cables You can arrange cable by inserting cable in the inner chassis seal yellow square as below picture Figure 3 14 Battery Replacement Step5 6 Slowing and carefully close the top chassis and avoid the cables Figure 3 15 Battery Replacement Step6 Note Please be careful for inserting cables and close the top chassis ...

Page 24: ...WISE 2410 User Manual 16 ...

Page 25: ...Chapter 4 4 System Configuration ...

Page 26: ...hrough https support advantech com support new_default aspx 2 Connect the module to your computer via the micro USB port 3 Execute WISE Studio 4 Clicking Go to Configuration while it shows available USB Serial in USB Serial box press Go To Configuration 5 Click Connect to link the WISE 2410 and the web configuration page will appear ...

Page 27: ...n in WISE Utility or press Open In Browser to open the web configuration in any browser Google Chrome is recommended 7 Click Information to check the basic information of the module 8 Click Configuration to use Information RF Module Time Date Scheduling Control Firmware settings ...

Page 28: ...tatus to check vibration and temperature data 4 1 2 LoRaWAN gateway WISE 6610 configuration 1 Default ID of WISE 6610 is 192 168 1 1 2 Login Username root Password root You can see the main page of Router you can change IP in LAN if needed ...

Page 29: ...tting Step1 Choose User Modules and LoRaWAN Gateway You can see WISE 6610N100 A Support NA frequency band make sure all of these parameters are matching with the RF module setting on WISE 2410 If you want to know any items description you can refer WISE 6610 user manual ...

Page 30: ...lick on Network Server http Account root Password root 4 1 3 Binding Process Between WISE 2410 and WISE 6610 This section will guide you to setup the connection between WISE 2410 and WISE 6610 1 Enter the Network Server http in WISE 6610 gateway as follow ...

Page 31: ...method The following flow will use ABP mode for description the binding process Note If select Commissioned which means the node will use OTAA mode for connecting with a gateway Note If select Active Nodes which means the node will use ABP mode for connecting with a gateway 3 Click Device Activated Nodes Create ...

Page 32: ...his demo a US version is used to connect with WISE 2410NA version C App Arguments the I O board of the end node In this demo a WISE 2410 is used D NwkSKey the network service key address of an end node Copy pate Networks Session Key from WISE 2410 RF module tab E AppSKey the application service key of an end node Copy pate Networks Session Key from WISE 2410 RF module tab F Click on save to finish...

Page 33: ...ck to WISE 2410 configuration setting page Click Configuration RF Module and choose LoRaWAN for RF operation mode setting on WISE 2410 5 Create a network server gateway Copy paste the MAC address from LoRaWAN radio LoRaWAN Gateway Identifier Then click on submit ...

Page 34: ...nection Verify A Click Application Server Status Here shows the end nodes if packets are received by gateway from an end node B Click Detail The gateway will help to pre parsing the data payload if the App Arguments input correctly ...

Page 35: ...er 4 System Configuration C Users can also access into Network Server http The Received frames page shows the received results The FCnt shows the frame sequence If this sequence is in continuously means some of the packets were lost ...

Page 36: ...ettings Schedule of when sensor should start mea surement System restart or reset to default Firmware download IO Status Display values which is measured by sen sors Include following types X Accelerometer Y Accelerometer Z Accelerometer Temperature Sensor related settings Site Survey Site Survey Tool for testing the communication quality between WISE 2410 wireless module with gateway Data Logger ...

Page 37: ...nce website Message ACK Advantech implement retry solution when WISE 2410 does not receive the acknowledgment from WISE 6610 or other 3rd party LoRaWAN gateway Time Date time zone settings Local Time WISE 2410 sync time with computer Daylight Saving Time Range setting for daylight saving time period Control System restart or reset to default Firmware Firmware Upload To update the firmware click Fi...

Page 38: ...Periodic interval 10 86400 sec Scenario A Sensing target every minutes Scenario B Sensing target on specific timing In this example Mon 8 00am Tue 8 00 am 4 2 3 IO Status Click IO Status to check vibration and temperature data 1 User can easily to see the detail data of all channels 2 User can choose channel 0 1 2 which means x y z axis to see the detailed vibration features Velocity RMS Accelerat...

Page 39: ...means X axis 1 means Y axis 2 means Z axis If the sensing target vibrate abnormally and pass through a threshold it can send alarm to LoRa gateway Temperature alarm Please select Channel 3 for Temperature sensor configuration If the sensing target temperature raise and pass through a threshold WISE will send alarm to a gateway ...

Page 40: ...stem powers on Not use for private server Circular Log when Memory Full Enable or Disable the Circular Operation for Built in Memory Not use for private server Log Data User can choose the log by channel or by sensor By Channel 0 means X axis 1 means Y axis 2 means Z axis 3 means Tem perature By Sensor Data from sensors including eigenvalues alarm trigger sensor status and raw data Logger Configur...

Page 41: ...ush Data Query Format UUID Enable or Disable the UUID MAC ID Enable or Disable the MAC ID Timestamp Local date and time GMT or Coordinated universal time UTC Query Filter Filter Mode User can choose No Filter Enable Time Filter or Amount of Lat est Data Query result as follow ...

Page 42: ...series there are two operation modes for querying vibration raw data Standard mode and Real Time mode Standard mode User could query get raw data which was previously measured and stored in WISE 2410 Real Time mode User could query get raw data which was measured by WISE 2410 in real time Press Get Raw Data button in WISE Studio ...

Page 43: ...mount of Latest data or Time Filter as query criteria to get raw data 2 Press Query button and 3 charts X Y Z axis will display If there are more than one record use could press Previous or Next to dis play selected record Recordt data could be exported as CSV file Please select file folder and press Export as CSV to export records ...

Page 44: ...the chart 4 3 2 Real Time operation mode 1 In Real Time operation mode user could get real time raw data Please check Export as CSV to export records before pressing Start button 2 Press Start button and there will be 3 charts X Y Z axis displayed in real time 3 Press Stop button to terminate data query ...

Page 45: ...Appendix A A WISE LPWAN Payload Format ...

Page 46: ...1 WHDR Header Frame Control 1 byte First Segment bit Set the First Segment bit to inform the server that this is the beginning of a packet with Total Length information of WISE payload data Frame Payload FRM Payload Octet 1 1 0 1 0 2 8 Variable 1 Frame Control Frame Sequence Number Total Length Source Address WISE LPWAN Payload CRC WHDR WPayload WCRC Frame Control bit 7 6 5 4 3 2 1 0 First Segment...

Page 47: ...Segment bit of Frame Control is set the Total Length octet will be added to signal the server the total bytes of WISE payload data Source Address 0 2 8 bytes optional None 2 LSB or 8 bytes of DevEUI according to the Address Mode bit of Frame Con trol If DevEUI is 74FE48FFFF19D121 the sequential order of 2 bytes address starts with D1 21 For complete DevEUI address the sequence will be 74 FE 48 FF ...

Page 48: ...t 7 5 MASK bit 4 0 Range 0x0 0x3 Temp Range 0x4 Accelerometer Bit 0 0 X axis Bit 1 0 Y axis Bit 2 0 Z axis Bit Range 0x0 0x3 Temp Range 0x4 Accelerometer Bit 0 Sensor Status 1 Byte Reserved Bit 1 Sensor Event 2 Bytes Sensor Event 2 Bytes Bit 2 Sensor Value 4 Bytes Reserved ...

Page 49: ...urtosis 2 Bytes Bit 4 Crest factor 2 Bytes Bit 5 Skewness 2 Bytes Bit 6 Standard deviation 2 Bytes Bit 7 Reserved Bit Range 0x0 0x3 Temp Humidity Bit 0 Sensor fail Bit 1 7 Reserved Bit Range 0x0 0x3 Temp Range 0x4 Accelerometer Bit 0 High alarm status 1 high alarm occurred 0 not occurred High alarm status of velocity RMS 1 high alarm occurred 0 not occurred Bit 1 Low Alarm Status 1 low alarm occur...

Page 50: ...r Source 1 byte Power source table is shown below Battery voltage 2 bytes The battery voltage with range 0 to 65 535V Timestamp 4 bytes Bit 0 Device event Bit 1 Power source Bit 2 Battery level Bit 3 Battery voltage Bit 4 Timestamp Bit 6 7 Reserved Bit Order Description 0 Battery low 2 7 Reserved Bit Order Description 0 Power line 1 Battery 3 7 Reserved ...

Page 51: ...sages 1st message 2nd nth messages The last message Frame Payload FRM Payload WHDR WPayload WCRC WHDR WPayload byte 1 1 1 0 Variable Frame Control Frame Sequence Number Total Length Source Address A partial of WISE Payload 0x80 S M WHDR WPayload byte 1 1 0 0 Variable Frame Control Frame Sequence Number Total Length Source Address A partial of WISE Payload 0x00 S 1 WHDR WPayload WCRC byte 1 1 0 0 V...

Page 52: ...WISE 2410 User Manual 44 ...

Page 53: ...Appendix B B Modbus address ...

Page 54: ...A Value of Vibration Velocity 0 01 mm sec Read 40502 1 Y Read 40503 2 Z Read 40504 3 Temp Temperature Value Read 40701 0 X Peak Value of Acceleration 0 001g Read 40702 1 Y Read 40703 2 Z Read 40721 0 X RMS of Acceleration 0 001g Read 40722 1 Y Read 40723 2 Z Read 40741 0 X Kurtosis 0 01 Read 40742 1 Y Read 40743 2 Z Read 40761 0 X Crest factor 0 01 Read 40762 1 Y Read 40763 2 Z Read 40781 0 X Skew...

Page 55: ...47 WISE 2410 User Manual Appendix B Modbus address ...

Page 56: ...are subject to change without notice No part of this publication may be reproduced in any form or by any means such as electronically by photocopying recording or otherwise without prior written permission of the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2020 ...

Reviews: