background image

Install the Hardware

Install Vlinx Manager Software

LED Status

1

4

2

1. 

Connect a 10-48 VDC (58VDC max.) power supply (6W 

required).

2. 

Connect the network cable from the serial server to a network 

drop using a standard network cable. 

3. 

Connect the serial device(s):

•  RS-232 with DB9: straight-through for DCE device, null 

modem for DTE device.

•  RS-232/422/485 with terminal blocks. See Appendix D in 

user manual for pinouts.

UL Installation - See Step #13 for more information.

1. 

Insert the included CD and it should autostart.

2. 

Follow the prompts to install the Vlinx Manager software.

     Note

: Be sure you have administrative rights & disable firewalls.

Set Up Vlinx Manager Software

5

1. 

Open Vlinx Manager, by clicking: 

Start > Programs > B&B Electronics > Vlinx > Vlinx Man-

ager > VESR Serial Server

The Discovery page opens.

Log In

6

1. 

Click 

Login

. (Password is blank from factory.)

The General page appears.

LED

STATUS

Ready

Blinks if system is operating correctly.

Port 1

ON indicates serial port open; blinks when data is present on serial port.

Port 2

Same as Port 1. (Present on 2-port units only.)

Link

ON indicates Ethernet operating in 100BaseTX; 

Blinks when data is present on Ethernet link.

Mode Switch

3

HOLD MODE SWITCH IN for...

RESULT

0 to 2 seconds

Initiates a Hardware Reset.

2 to 10 seconds

Enters Console Mode.

Over 10 seconds

Reset to Factory Defaults.

2. 

To configure via the network, select 

Network

.

3. 

If you know the IP address, select 

“The device is at this ad-

dress”,

 and type in the address. If not, select 

“I don’t know the 

IP address of the device.”

4. 

Click 

Connect

.

OR...Set Up the Web Interface:

1. 

Open a browser and type the IP address of the serial server in 

the Address Bar.

2. 

When the serial server is found, the Configuration window 

appears.

Set Up Network

7

•  The serial server is set at the factory to receive an IP assign-

ment from a DHCP server. If a DHCP server is not available 

on your network, it will default to 

169.254.102.39.

•  If this address does not work with your PC, change your 

network settings to:

•  IP Address = 169.254.102.1

•  Subnet Mask = 255.255.255.0

•  Default Gateway = 169.254.102.100

Note

: If you need different settings, refer to User Manual, Chapter 4.

Set Up Serial Port Parameters

8

1. 

Click 

Port 1 Serial 

to open the Serial Port Parameters page. 

Select the type of serial connection between the serial server 

and the serial device (RS-232, RS-422, RS-485 2-wire, or 

RS-485 4-wire).

2. 

Select the Baud Rate, Data Bits, Stop Bits, Parity and Flow 

Control needed to communicate with the serial device.

3. 

If your serial server is 2 port, select the next port in the de-

scription box, then repeat the previous steps.

4. 

Click 

Next

.

Set Up Port Network Parameters

9

1. 

Click 

Port 1 Network 

to open the Port Network Parameters 

page.

2. 

Select the type of network protocol you want to use: TCP, 

UDP, VCOM or Paired Mode.

3. 

If you select TCP, select whether the serial server will oper-

ate as a Client or Server, then configure the required IP ad

-

dress, port numbers and other related parameters.

4. 

If you select UDP, configure the IP addresses, ports and 

other related parameters for the devices you want to receive 

from and send to.

Reviews: