12.
Make sure user not to contact SIP/SOPs and the patient at the same time.
13.
Do not switch on/off the power switch of the battery system during operation.
Warning!
To avoid risk of electric shock, this equipment must only be connected
to a supply mains with protective earth.
Warning!
No modification of this equipment is allowed.
14.
The power cord for use on the device shall be no less robust than ordinary
tough rubber sheathed flexible cord (IEC 60245-1:2003, Annex A, designation
53) or ordinary polyvinyl chloride sheathed flexible cord (IEC 60227-1:1993,
Annex A, design. 53. For the US/CA the requirements of the NEC and Canadian
code shall be followed (US and CA national differences).
Warning!
Battery system, equipotential pin, metal wiring on equipotential pin,
wheels and brake shall be replaced/send back to maintain by the manu-
facturer every two years, risks of function failure, electrical shock, equip-
ment damage, environment pollution and etc. may occur if not doing so.
15.
If your computer clock is unable to keep accurate time or the BIOS configuration
resets to default, please check the battery.
Caution!
Do not replace the battery yourself. Please contact a qualified technician
or your retailer.
The computer is provided with a battery-powered real-time clock circuit.
There is a danger of explosion if battery is incorrectly replaced. Replace
only with same or equivalent type recommended by the manufacturer.
Discard used batteries according to the manufacturer's instructions.
Caution!
When servicing the device, always use replacement parts that meet
Advantech standards. Advantech Medical cannot warrant or endorse
the safe performance of third-party replacement parts for use with our
medical device.
Caution!
Application User: This device is provided to professional
nurses/caregivers and technicians. Cannot be used by people other
than nurses/caregivers and technicians
16.
CLASSIFICATION:
Supply Medical Grade adapter (IEC-60601-1-2)
No applied part
IP65 front panel
Continuous Operation