PCM-5862E/EL User's Manual
80
Programming the Watchdog Timer
In order to program the watchdog timer, you must write a program
which writes I/O port address 443 (hex). The output data is a value of
time interval. The value range is from 01(hex) to 3F(hex), and the
related time interval is 1 sec. to 63 sec.
Data
Time Interval
01
1 sec.
02
2 sec.
03
3 sec.
04
4 sec.
.
.
.
3F
63 sec.
After data entry, your program must refresh the watchdog timer by
rewriting the I/O port 443 (hex) while simultaneously setting it. When
you want to disable the watchdog timer, your program should read I/O
port 443 (hex).
The following example shows how you might program the
watchdog timer in BASIC:
10
REM Watchdog timer example program
20
OUT &H443, data REM Start and restart the watchdog
30
GOSUB 1000 REM Your application task #1
40
OUT &H443, data REM Reset the timer
50
GOSUB 2000 REM Your application task #2
60
OUT &H443, data REM Reset the timer
70
X=INP (&H443) REM Disable the watchdog timer
80
END
1000
REM Subroutine #1, you application task
.
.
.
1070
RETURN
2000
REM Subroutine #2, you application task
.
.
.
2090
RETURN
Summary of Contents for PCM-5862E
Page 14: ...6 PCM 5862E EL User s Manual...
Page 40: ...32 PCM 5862E EL User s Manual...
Page 48: ...40 PCM 5862E EL User s Manual...
Page 78: ...70 PCM 5862E EL User s Manual...
Page 86: ...78 PPC 120 140 User s Manual...
Page 92: ...84 PCM 5862E EL...
Page 113: ...105 Appendix D Optional Extras D Optional Extras A P P E N D I X...
Page 116: ...108 PCA 582E EL User s Manual...
Page 117: ...109 Appendix E Mechanical Drawing E Mechanical Drawing A P P E N D I X...