PCL-813 User's Manual
Two Parameter Tables are defined in this example, Jobs 1 and 2 are
the same, except for the start channel, stop channel and gain setting.
NOTE:
NOTE:
NOTE:
NOTE:
NOTE:
1). When using BASIC language, negative numbers must be used to
represent integer data over 32767.
2). Negative number = integer - 65536.
3). For example, you need to pass 45000 as a input parameter to
BASIC function: 45000 - 65536 = -20536. So you have to use -
20536 rather than 45000 as a parameter for the BASIC function.
Parameter List
Name
Name
Name
Name
Name
Size
Size
Size
Size
Size
Index
Index
Index
Index
Index
Board
number
1
word
Param[0]
Base
I/O
address
1
word
Param[1]
Reserved
1
word
Param[2]
Reserved
1
word
Param[3]
Reserved
1
word
Param[4]
Reserved
2
words
Param[5]
Reserved
1
word
Param[7]
Reserved
1
word
Param[8]
Reserved
1
word
Param[9]
A/D
Data
Buffer
A’s
address
2
words
Param[10]
A/D
Data
Buffer
B’s
address
2
words
Param[12]
A/D
conversion
number
1
word
Param[14]
A/D
start
channel
1
word
Param[15]
A/D
stop
channel
1
word
Param[16]
Overall
gain
code
1
word
Param[17]
Gain
code
array
pointer
2
words
Param[18]
Error
number
1
word
Param[45]
Return
value
0
1
word
Param[46]
Return
value
1
1
word
Param[47]