13
PCIE-1762H User Manual
Chapter 3
S
ignal Connections
3.3
Relay Connections
After power on, the initial relay output status of the PCIE-1762H card should be as
shown in Figure 3.2 below.
Figure 3.2 Relay Output Connections
A write operation to I/O address, BASE +0, will change the output status of each
relay. For example, if Bit 0 of BASE +0 is set to “1” (logic high), relay 0, K0, will switch
from the “Normally Closed” position (NC0) to the “Normally Open” position (NO0).
This means that LOAD2 will be de-energized, while LOAD1 is energized.
To summarize, the “Common” line connects to the “Normally Closed” line if the corre-
sponding bit is set as 0 (power-on initial status). Otherwise, if the corresponding bit is
set as 1, then the “Common” line will connect to the “Normally Open” line.
Summary of Contents for PCIE-1762H
Page 1: ...User Manual PCIE 1762H 16 Channel Relay and 16 Channel Isolated Digital Input PCIe Card ...
Page 6: ...PCIE 1762H User Manual vi ...
Page 7: ...Chapter 1 1 Overview ...
Page 11: ...Chapter 2 2 Installation ...
Page 16: ...PCIE 1762H User Manual 10 ...
Page 17: ...Chapter 3 3 Signal Connections ...
Page 20: ...PCIE 1762H User Manual 14 ...
Page 21: ...Appendix A A Specifications ...
Page 24: ...PCIE 1762H User Manual 18 ...
Page 25: ...Appendix B B Block Diagram ...
Page 26: ...PCIE 1762H User Manual 20 B 1 Block Diagram Appendix A ...
Page 27: ...21 PCIE 1762H User Manual Appendix B Block Diagram ...