background image

2  PCA-6013 Startup Manual

  Jumpers and Connectors 

 

The board has a number of connectors and jumpers that 

allow you to configure your system to suit your application.
The table below lists the function of each of the connectors 
and jumpers.

Connectors

Label

Function

IDE1

IDE connector

FDD1        

Floppy drive connector

LPT1        

Parallel port

VGA1

VGA connector

COM12      

RS232 serial ports connector

KBMS1      

PS/2 keyboard and mouse connector

KBMS2      

External keyboard/mouse connector

JIR1

Infrared connector

JOBS1

HW Monitor Alarm

Close: Enable OBS Alarm

Open: Disable OBS Alarm

CPUFAN1        CPU FAN connector
JFP1      

Power and Reset Button connector

JFP2      

HDD LED/Speaker connector

JFP3      

Power LED and keyboard lock connector

LAN1

LAN RJ45 connector

LAN2

LAN RJ45 connector (only for G2 SKU)

LANLED1

LAN LED connector

HDAUD1

HD Audio connector

SATA1 

Serial ATA1

SATA2

Serial ATA2

SATA3 

Serial ATA3

USB12

Two USB port pin headers

USB34

Two USB port pin headers

USB56

Two USB port pin headers

USB78

Two USB port pin headers

USB9

One USB port on I/O bracket (only for 

G2 SKU)

DIMM1

Memory connector channel A

LPC1

Low pin count connector

JCASE1

Case open

ATXF1

ATX power connector

GPIO1

GPIO connector

SMBUS1

SMBUS connector

CF1

CF socket (only for G2 SKU)

Jumpers

Label

Function

CMOS1

CMOS clear

JWDT1

Watchdog timer output selection

JLVDS1

3.3 V / 5 V, LVDS voltage selection

JVBR1

LVDS backlight setting

CMOS1: CMOS clear function

Closed Pins

Result

1-2

Keep CMOS data *

2-3

Clear CMOS

JWDT1: Watchdog timer output option

Closed Pins

Result

1-2

IRQ11

2-3

System reset *

 

  Software Installation 

The CD disc contains a driver installer program that will lead 

you through the installation of various device drivers needed 

to take full advantage of your CPU card.

  Caution 

                     

The computer is provided with a battery-powered 

real-time clock circuit. There is a danger of explo-
sion if battery is incorrectly replaced. Replace 
only with same or equivalent type recommended 
by Advantech. Discard used batteries according 
to manufacturer’s instructions.

  Safety Information

 

This device complies with the requirements in Part 15 of 

the FCC rules. Operation is subject to the following two 

conditions.
1.  This device may not cause harmful interference.
2.  This device must accept any interference received, 

including interference that may cause undesired opera-

tion.

1

2

3

* default setting

1

2

3

* default setting

Reviews: