Troubleshooting
Problem
Possible Cause
Unit won’t work and is
plugged in.
Check plug input to unit,
then check fuse.
Unit will sift, but not
pulse.
Pulse timer inoperative.
Call for technical support.
Unit comes on, but will
not sift or pulse.
Make sure stack assembly
is inserted correctly. If
the stack assembly is not
the problem, the cam
assembly may be out of
alignment or the trigger
spring may be broken.
Unit works, but shuts off
before timer hits zero.
Stack assembly has not
been unlatched.
Unit works, but no light
comes on.
Replace the starter, which
is located in the upper left
hand corner of the
chamber. Also check the
light bulb.
Unit runs but lacks
power.
Possible defective driver
or defective power
transformer