form of this command to disable
the port.
show interface configuration
I
show interface configuration status
switch(config)#
interface fastEthernet 2
switch(config-if)#
show interface configuration
show interface status
I
show interface actual status
switch(config)#
interface fastEthernet 2
switch(config-if)#
show interface status
show interface accounting
I
show interface statistic counter
switch(config)#
interface fastEthernet 2
switch(config-if)#
show interface accounting
no accounting
I
Clear interface accounting
information
switch(config)#
interface fastEthernet 2
switch(config-if)#
no accounting
3.2.5
Trunk Commands Set
Table 3.5: Trunk Commands Set
Command
Level
Description
Example
aggregator priority
[1~65535]
G
Set port group system priority
switch(config)#
aggregator priority 22
aggregator activityport
[
Group ID
]
[Port Numbers]
G
Set activity port
switch(config)#
aggregator activityport 2
aggregator group
[GroupID] [Port-list]
lacp
workp
[Workport]
G
Assign a trunk group with LACP
active.
[GroupID] :1~3
[Port-list]:Member port list, This
parameter could be a port
range(ex.1-4) or a port list separate
by a comma(ex.2, 3, 6)
[Workport]: The amount of work
ports, this value could not be less
than zero or be large than the
amount of member ports.
switch(config)#
aggregator group 1 1-4 lacp workp
2
or
switch(config)#
aggregator group 2 1,4,3 lacp
workp 3
aggregator group
[GroupID] [Port-list]
nolacp
G
Assign a static trunk group.
[GroupID] :1~3
[Port-list]:Member port list, This
parameter could be a port
range(ex.1-4) or a port list separate
by a comma(ex.2, 3, 6)
switch(config)#
aggregator group 1 2-4 nolacp
or
switch(config)#
aggregator group 1 3,1,2 nolacp
show aggregator
P
Show the information of trunk group
switch#
show aggregator 1
or
switch#
show aggregator 2
or
switch#
show aggregator 3
no aggregator lacp
[GroupID]
G
Disable the LACP function of trunk
group
switch(config)#
no aggreator lacp 1
no aggregator group
[GroupID]
G
Remove a trunk group
switch(config)#
no aggreator group 2
3.2.6
VLAN Commands Set
Table 3.6: VLAN Commands Set
Command
Level
Description
Example
vlan database
P
Enter VLAN configure mode
switch#
vlan database
Vlanmode
V
To set switch VLAN mode.
switch(vlan)#
vlanmode portbase
EKI-7656C_7656CI_Manual
32
Summary of Contents for eki-7656c
Page 1: ...EKI 7656C 7656CI 16 2G port Industrial Managed Redundant Gigabit Ethernet Switch User Manual...
Page 10: ...Appendix B Compatible SFP Transceivers 104 EKI 7656C_7656CI_Manual x...
Page 18: ...EKI 7656C_7656CI_Manual 8...
Page 21: ...2 2 Dimensions units mm Figure 2 2 1 Front View 11 Chapter2...
Page 22: ...Figure 2 2 2 Side View EKI 7656C_7656CI_Manual 12...
Page 23: ...Figure 2 2 3 Rear View 13 Chapter2...
Page 24: ...Figure 2 2 4 Top View EKI 7656C_7656CI_Manual 14...
Page 64: ...Figure 3 3 14 Event Configuration EKI 7656C_7656CI_Manual 54...
Page 73: ...Figure 3 3 21 Work ports with LACP enabled 63 Chapter3...
Page 91: ...Figure 3 3 39 SNMP V3 configuration interface 81 Chapter3...
Page 93: ...Figure 3 3 40 QoS Configuration interface 83 Chapter3...
Page 106: ...EKI 7656C_7656CI_Manual 96...
Page 107: ...97 Troubleshooting CHAPTER...
Page 109: ...99 Pin Assignments Wiring APPENDIX...
Page 112: ...EKI 7656C_7656CI_Manual 102...